Ariston GENUS PREMIUM EVO HP 65 Tasarım, Kurulum ve Servis Talimatları - Sayfa 38
Kazan Ariston GENUS PREMIUM EVO HP 65 için çevrimiçi göz atın veya pdf Tasarım, Kurulum ve Servis Talimatları indirin. Ariston GENUS PREMIUM EVO HP 65 44 sayfaları. Wall-hung condensing
gas boiler hp
Ayrıca Ariston GENUS PREMIUM EVO HP 65 için: Kullanıcı Kılavuzu (17 sayfalar), Kullanıcı Kılavuzu (24 sayfalar), Kullanıcı Kılavuzu (32 sayfalar)
maintenance
Instructions for opening the casing and performing an
internal inspection (45/65)
Before performing any work on the boiler, fi rst disconnect it from
the electrical power supply using the external bipolar switch and
shut off the gas valve.
To access the inside of the boiler, the following is necessary:
1. Remove the casing by unhooking it from the control panel (a)
2. Loosen the two screws on the front casing (b), pull it forwards
and unhook it from the upper pins (c)
3. Rotate the control panel, pulling it forwards (d)
4. Unhook the two clips on the panel closing off the combustion
chamber. Pull it forwards and unhook it from the upper pins (e).
(a)
(b)
(c)
38
(d)
Instructions for opening the casing and performing an
(85/100/115/150)
internal inspection
Before performing any work on the boiler, fi rst disconnect it from
the electrical power supply using the external bipolar switch and
shut off the gas valve.
To access the inside of the boiler, the following is necessary:
1. Loosen the two screws on the front casing (a), pull it forwards
and unhook it from the upper pins (b)
2. girar el panel de mandos tirándolo hacia delante;
3. Unhook the two clips on the panel closing off the combustion
chamber. Pull it forwards and unhook it from the upper pins (c).
(a)
(c)
(b)