Ariston microGENUS 27 MFFI Servis Talimatları - Sayfa 10

Kazan Ariston microGENUS 27 MFFI için çevrimiçi göz atın veya pdf Servis Talimatları indirin. Ariston microGENUS 27 MFFI 28 sayfaları. Type c boilers
Ayrıca Ariston microGENUS 27 MFFI için: Kurulum Talimatları Kılavuzu (25 sayfalar), Kullanıcı Kılavuzu (24 sayfalar), Servis Talimatları (28 sayfalar)

Ariston microGENUS 27 MFFI Servis Talimatları
Soft-light
Adjustment
10. Remove the pipe from the pressure gauge and connect
screw "C" to the pressure outlet in order to seal off the
gas.
11. Carefully check the pressure outlets for gas leaks (valve
inlet and outlet).
IMPORTANT!
Whenever you disassemble and reassemble the gas
connections, always check for leaks using a soap and water
solution.
10
Supplied By www.heating spares.co Tel. 0161 620 6677
61.eps
Max Heating
Adjustment
VR015A.eps

Removing the spark generator

1. Disconnect ignition leads "T" by pulling upward
(F
. 1.27);
IG
2. Remove the screw "V" (F
3. Remove the spark generator (F
45.eps
43.eps
44.eps
. 1.28);
IG
. 1.29).
IG
T
F
. 1.27
IG
V
F
. 1.28
IG
F
. 1.29
IG
B063