Ariston Type C Kurulum Talimatları Kılavuzu - Sayfa 7

Kazan Ariston Type C için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. Ariston Type C 25 sayfaları. Type c boilers
Ayrıca Ariston Type C için: Kurulum Talimatları Kılavuzu (25 sayfalar), Kurulum Talimatları Kılavuzu (48 sayfalar), Kurulum ve Servis Talimatları (49 sayfalar), Kurulum Talimatları Kılavuzu (44 sayfalar)

Ariston Type C Kurulum Talimatları Kılavuzu
2.7
G
C
AS
ONNECTION
2.8
W
C
ATER
ONNECTIONS
KT003A
F
. 2.5
IG
Note: The diagrams for the electrical system are indicated in section 2.11.
Warning, this appliance must be earthed.
External wiring to the appliance must be carried out by a competent person
and be in accordance with the current I.E.E. Regulations and applicable
local regulations. The microCombi is supplied for connection to a 230 V
50 Hz supply.
The supply must be fused at 3 A.
The method of connection to the electricity supply must facilitate complete
electrical isolation of the appliance, by the use of a fused double pole
isolator having a contact separation of at least 3 mm in all poles or
alternatively, by means of a 3 A fused three pin plug and unswitched
shuttered socket outlet both complying with BS 1363.
The point of connection to the Electricity supply must be readily accessible
and adjacent to the appliance unless the appliance is installed in a bathroom
when this must be sited outside the bathroom (see section 2.2).
The local gas region contractor connects the gas meter to the service pipe.
If the gas supply for the boiler serves other appliances ensure that an
adequate supply is available both to the boiler and the other appliances
when they are in use at the same time.
Pipe work must be of an adequate size. Pipes of a smaller size than the
boiler inlet connection should not be used.
V
IEW OF THE
F F
F
. 2.4
IG
L
:
EGEND
A = Central Heating Flow
B = Domestic Hot Water Outlet
C = Gas Inlet
D = Domestic Cold Water Inlet
E = Central Heating Return
F = Safety Valve
C
H
ENTRAL
EATING
Detailed recommendations are given in BS 6798:1987 and BS 5449-1:1990,
the following notes are given for general guidance.
7
B
C
OILER
ONNECTIONS
~
SC005A