Aeotec 7 Pro ZWA012 Kullanıcı Kılavuzu - Sayfa 13
Güvenlik Sensörleri Aeotec 7 Pro ZWA012 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Aeotec 7 Pro ZWA012 14 sayfaları. Door / window sensor
Aeotec Door/Windows Sensor 7 Pro User guide : Aeotec Help Desk
Size: 1 Byte, Default Value: 0
Setting Description
0
OFF when sensor is vertical
1
ON when sensor is vertical
Parameter 17: 5th Association Group Trigger
This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of
Association Group 5.
Size: 1 Byte, Default Value: 0
Setting Description
0
Switch after Open and Close
1
Switch after Open
2
Switch after Close
Parameter 18: Command Sent to Devices of Association Group 5
This parameter defines which commands is sent to 5th Association Group
Size: 1 Byte, Default Value: 2
Setting Description
0
On
1
Off
2
On and Off
Parameter 19: BASIC command value sent to 5th Association Group on On event
This is the BASIC command value sent in case of On event.
Size: 1 Byte, Default Value: 255
Setting Description
allow setting an associated device to a
0 - 99
specified level. (0 is OFF)
255
ON
Parameter 20: BASIC command value sent to 5th Association Group on Off event
This is the BASIC command value sent in case of Off event.
Size: 1 Byte, Default Value: 0
Setting Description
allow setting an associated device to a
0 - 99
specified level. (0 is OFF)
255
ON
13 z 14
https://aeotec.freshdesk.com/support/solutions/articles/6000230465
23. 2. 2021, 19:15