Setting
0
256
257
Parameter 10: Set the alarm time for the Buzzer when the sensor is triggered.
Set the alarm time for the Buzzer when the sensor is triggered.
Size: 4 Byte, Default Value: 101968650
Setting
1 - 255
256 - 65535
65536 - 2147483647
Parameter 39: Configure the default low battery value.
Configure the default low battery value. When the current battery level is lower than this value, it will send out the low battery alarm.
Size: 1 Byte, Default Value: 20
Setting
10 - 50
Parameter 48: Enable/disable the sensor report
Enable/disable the sensor report
Size: 1 Byte, Default Value: 0
Setting
0
1
2
4
16
32
Parameter 49: Set the upper limit value (overheat).
Set the upper limit value (overheat).
Size: 4 Byte, Default Value: 68157696
Setting
0
1
65536 - 2147483647
Parameter 50: Set the lower limit value (under heat)
Set the lower limit value (under heat)
Size: 4 Byte, Default Value: 20971776
Setting
0
1
65536 - 2147483647
Parameter 57: Set the recover limit value of temperature sensor.
Note:1. When the current measurement <= (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next
measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement <= (Upper limit - Recover limit).2. When
the current measurement >= (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement
is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit).3. High byte is the
recover limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit).
Size: 2 Byte, Default Value: 5121
Description
USB power mode
Keep sleep state for Battery power mode
Keep awake for 10 minutes for battery power mode.
Description
Repeated cycle of Buzzer alarm.
the time of Buzzer keeping ON state (MSB)
The time of Buzzer keeping OFF state
Description
Available rang is 10% to 50%.
Description
Disable
Notification Report for Water Leak event
Notification Report for Vibration event
Configuration Report for Tilt sensor
Notification Report for Under heat alarm
Notification Report for Overheat alarm
Description
Celsius unit
Fahrenheit unit
Temperature value
Description
Celsius unit
Fahrenheit unit
Temperature value