Ariston CX65SM2 X AUS Kullanım Talimatları Kılavuzu - Sayfa 4

Fırın Ariston CX65SM2 X AUS için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Ariston CX65SM2 X AUS 12 sayfaları. Cooker and oven
Ayrıca Ariston CX65SM2 X AUS için: Kullanım Talimatları Kılavuzu (12 sayfalar)

Ariston CX65SM2 X AUS Kullanım Talimatları Kılavuzu
How to connect an alternative plug
GB
GREEN &
YELLOW
BROWN
BLUE
Once the appliance has been installed, the power
supply cable and the electrical socket must be
easily accessible.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced
by authorised technicians only.
The manufacturer declines any liability should
these safety measures not be observed.

Gas connection

Connection to the gas network or to the gas cylinder
may be carried out using a flexible rubber or steel
hose, in accordance with current national legislation
and after making sure that the appliance is suited to
the type of gas with which it will be supplied (see the
rating sticker on the cover: if this is not the case see
below). When using liquid gas from a cylinder, install a
pressure regulator which complies with current national
regulations. To make connection easier, the gas
supply may be turned sideways*: reverse the position
of the hose holder with that of the cap and replace the
gasket that is supplied with the appliance.
Check that the pressure of the gas supply is
consistent with the values indicated in the Table of
burner and nozzle specifications (see below). This
will ensure the safe operation and durability of your
appliance while maintaining efficient energy
consumption.
4
All manuals and user guides at all-guides.com
The wires in this mains
lead are coloured in
accordance with the
following code:
13 amp fuse
BLUE “NEUTRAL” (N)
BROWN “LIVE” (L)
CROSS-BAR
CORD GRIP
GREEN AND YELLOW
“EARTH” (E)
Gas connection using a flexible rubber hose
Make the connection using a gas hose that complies
with requirements set forth by the current National
Regulations. The appliance is factory set for
connection to a natural gas supply. A fitting "R" with
L
G
R
before unscrewing the metal pipe bolt. This is to
prevent the fitting "R" from slipping and so as not to
cause any leaks from sleeve "L". If the appliance is
designed for left and right gas connection, the cap
should be inverted and the seal supplied with the
appliance should be replaced when changing the
connection.
Once the connection has been performed, make
sure that the hose:
• Does not come into contact with any parts that
reach temperatures of over 50°C.
• Is not subject to any pulling or twisting forces and
that it is not kinked or bent.
• Does not come into contact with blades, sharp
corners or moving parts and that it is not
compressed.
• Is easy to inspect along its whole length so that
its condition may be checked.
• Is shorter than 1500 mm.
• Fits firmly into place at both ends, where it will be
fixed using clamps that comply with current
regulations.
If one or more of these conditions is not fulfilled or
if the cooker must be installed according to the
conditions listed for class 2 - subclass 1 appliances
(installed between two cupboards), the flexible steel
hose must be used instead (see below).
a conical thread ISO7-1
(1/2 gas) and a seal "G"
is fitted at the end "L"
of the pipe to be
connected to the gas
mains. This fitting
should not be removed.
When the connection
pipe (flexible or rigid) is
dismounted, the fitting
"R" should be locked in
place using a spanner