Parameter 2: Minimum humidity change to report
This value defines the minimum change of humidity to cause an unsolicited report of humidity to the
central controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when
the humidity changes. However, periodic reports, managed by configuration parameter 4, may still be
active.
Size: 1 Byte, Default Value: 5
Setting
0
1 - 20
Parameter 3: Check interval for minimum change on parameter 1 and 2.
This value determines how often aerQ Sensor checks for minimum change in temperature or humidity
on Parameter 1 and 2 or when the Sensor wakes up by button pressing. Value is set in minutes.
Size: 1 Byte, Default Value: 15
Setting
1 - 255
Parameter 4: Periodic Reports
This parameter defines the time interval to send an unsolicited report. If the value is set to 0, there will be
no periodic reports sent to the controller. However, reports on temperature/humidity changes, managed
by configuration parameters 1 and 2 may still be active.
Size: 2 Byte, Default Value: 43200
Setting
0
30 - 65535
Parameter 5: Temperature Upper Watermark value
This parameter defines a temperature. If the measured temperature surpasses this watermark, a BASIC
command is sent into Association Group 2. The Sensor will check the watermark value for an interval set
by Parameter 16 or when the Sensor wakes up by button pressing.
Size: 2 Byte, Default Value: 0, Unit=0.1 degree
Setting
disabled
0.1-10 degree
Description
disabled
1-20%
Description
1 - 255 minutes
Description
disabled
Seconds
Description