3Com 3C16075 Kurulum Kılavuzu - Sayfa 10

Ağ Donanımı 3Com 3C16075 için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. 3Com 3C16075 12 sayfaları. Superstack 3 advanced rps type 3 power module

10
S
S
UPER
TACK

Connecting the DC Cables

Standard Type 3 Module DC Cable
To connect a standard Type 3 Module DC cable (supplied with this
module) to provide redundancy to your SuperStack 3 unit:
1 Ensure the Type 3 Power Module is in the Advanced RPS chassis
before connecting or disconnecting a standard DC cable or the
protective cover.
CAUTION: An energy hazard may exist on the Type 3 Power Module
DC connector when the Module is in the Advanced RPS chassis.
2 Check that you are about to connect the Type 3 Module (3C16075)
with the Type 3 standard DC cable supplied with the module.
3 Connect the cable's male connector to the Redundant Power System
socket on the rear of the SuperStack 3 unit.
4 Connect the cable's female connector to the Type 3 Module outlet
fitted into the rear of the Advanced RPS chassis.
5 Tighten the screws on all DC cable connectors with a suitable tool.
Optional 'Y' DC Cable
To connect the 'Y' cable (3C16077) to provide full redundancy
(resilience) to your SuperStack 3 unit:
1 Ensure the Type 3 Power Module is in the Advanced RPS chassis
before connecting or disconnecting the optional 'Y' DC cable.
CAUTION: An energy hazard may exist on the Type 3 Power Module
DC connector when the Module is in the Advanced RPS chassis.
2 Check that you are about to connect Type 3 Modules (3C16075) with
the Type 3 'Y' cable (3C16077).
3 Connect the male connector to the Redundant Power System socket
on the rear of the SuperStack 3 unit.
4 Connect one female connector to each of two Type 3 Module outlets
fitted into the rear of the Advanced RPS chassis.
5 Tighten the screws on all DC cable connectors with a suitable tool.
Further details of how to use the 'Y' cable are given in the guide that
accompanies the cable.
® 3 A
RPS T
DVANCED
3 P
M
YPE
OWER
ODULE
(3C16075) I
NSTALLATION
G
UIDE