Location of washer:
C.eo iooa.oo
where
washer
w,,,
be,nsta,ed.
Make
sure
you h ave everyth,ng
necessary
for correct
installation.
Proper
imtalIation
is your
responsibilRy.
ao. cold
Recessed
area
(nstructJons
Grounded
eJectrka[
outlet
is reqored
wRhin 5 feet of upper
right corner of washer
cabinet. See "Electrical
requirements,"
Panel A.
The hot and cold water
inlets on the back of the
washer have 3/4 --
11d/2
American hose
coupling standard
threads.
Support:
Floor must be
sturdy enough to
support washer weight
(with water) of 315
pounds.
To use drain hose
shipped with washeB
standpipe, laundry
tub or utility sink
should be within 46
inches of the washer
drain connector:
mmportant: Observe
all governing
codes
and ordinances,
-washer
drain
connector
Should be within
3-1/2 feet of upper
right hand corner of
washer cabinet (if
not, see chart below).
Provide water
pressure 5ol 00 psi.
Water
heater:
Set to deliver
140°F water
to washer:
Do
Not
store
or
[f your
home
has:
You wlH need
to buy:
39" high, 2" dia. standpipe
nothing.
If your installation is different,
see "Drain system" bdow.
1" dia. standpipe
2" dia. to 1" dia. standpipe adapter, Part No. 3363920.
floor drain
siphon break, Part No. 285320;
additional
drain hose, Part No.
3357090; and Connector
Kit, Part No. 285442.
overhead sewer
standard 20 ga!, 34" high laundry tub or utility sink, sump pump
and connectors
(available from Ioca! plumbing
suppliers).
standard 20 ga!., 34" high laundry
nothing.
tub or utility sink
water not dose by
2 longer water inlet hoses: 6 ft. hoses, Part No. 76313 or
10 ft. hoses, Part No. 350008.
Parts listed are available from your loca! dealer or authorized parts distributor.
This washer
may be installed
in a recessed
area or closet,
The installation dimensions
openings in top and bottom of
shown are the minimum
door are required
Louvered doors
spaces allowable. Additional
with air openings in top and
spacing should be considered
bottom are acceptable. Companion
for ease of installation and
appliance spacing should be
servicing. If closet door is
considered.
installed, the minimum
air
/
closet
door
48 sq. in.
24 sq. in.
O
48 sq. in.
C
24 sq. in.
7-
* Additional
clearances for wall, door and floor
moldings
may be
required.
Remove
parts package.
Untape
and open
washer
lid. Remove
literature
package
from
washer.
Drai_
_"__y_wt_e_:
Look at drain
systems
below
to decide
which
system
to use.
4 I'
min.
Needs a 20-gallon laundry tub.
:3. :$tandp[
drain system:
Needs
a twodnch
minimum
diameter
standpipe
with
minimum
carry-away
capacity
of 1 7 gallons
per minute.
A 2" dia. to 1" dia. standpipe
adapter,
Part No.
3363920,
must be used with
1" dia. drain
systems.
Wall
standpipe
draio
Top of tub must be at
least 34 inches high
and no higher than
96 inches from
bottom
of washer.
uires
a
Part No.
285320.
Siphon
break must be
above high-
water
[eve[ in
washer,
at least
28 inches from
bottom
of
washer.
Additional
drain
hose wiJ[ be
needed.
See
above.
Floor
standpipe
drain
Top of
standpipe
must be at
least 39
inches high
and no
34"
higher
than
96 inches**
from
bottom
of
washer.
**If the drain
height
is greater
than 96 inches, a sump pump system must be used.
If a longer
drain
hose is needed,
use complete
drain
hose assembly
(56 inches
long),
Part No. 661575,
or drain
hose (21 inches
long),
Part No. 3357090,
and
Connector
Kit, Part No. 285442.
These kits are available
from
your
local dealer
or an authorized
parts distributor.
Electrical
requirements
Electrical
Shock Hazard
Plug into a grounded
a-prong
outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
FaUure to follow these
instructions can result in
death, fire, or electrical
shock.
Panel A
if codes
permit
aod
a separate
grouod
wire
Js used,
it ls
recommeoded
that
a qualified
electrician
determJoe
that
the
grouod
path
is adequateo
Do
Not
grouod
to
a gas
pipeo
Check
with
a qualified
electr[cJao
if
you
are
oot
sure
the
washer
ls
properly
grounded.
Do
Not
have
a fuse
io the
neutral
or
grouod
circuit.
A 120-volt, 60-Hz, Ac-only, 15- or
20-ampere, fused electrical supply is
required. Timedelay
fuse or circuit
breaker is recommended.
It is
recommended
that a separate circuit
serving only this appliance be provided.
Recommended
glround
method
3-pron 9
ground-type
outlet
j
......
m
_'_r
_r3_e r supply
For your personal safety, this washer must
be grounded.
This washer is equipped with
a power supply cord having a 3-prong
ground plug.
To minimize
possible shock hazard,
the cord must be plugged into a mating, 3_
prong, ground-type
outlet, grounded in
accordance with local codes and
ordinances.
If a mating outlet is not
available, it is the personal responsibility
and
obligation
of the customer to have the
properly grounded outlet installed by a
qualified electrician.
WARNING
Improper connection
of the equipment-grounding
conductor
can result in a risk of electric shock. Check with a qualified electrician or
serviceman if you are in doubt as to whether the appliance is properly
grounded.
Do not modify the plug provided with the appliance - if it will
not fit the outlet, have a proper outlet installed by a qualified electrician.