Whirlpool GSC25C6EYW Kullanıcı Talimatları - Sayfa 12
Buzdolabı Whirlpool GSC25C6EYW için çevrimiçi göz atın veya pdf Kullanıcı Talimatları indirin. Whirlpool GSC25C6EYW 44 sayfaları. Sxs xxl refrigerators water filter housing/door misaligned
Ayrıca Whirlpool GSC25C6EYW için: Ürün Boyutları (1 sayfalar), Enerji Kılavuzu (2 sayfalar), Teknik Servis Pointer (4 sayfalar)
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50% reduction
*
Particulate Class I
85% reduction
Contaminant
NSF Reduction
Reduction
Requirements
Live Cysts
†
99.95%
Asbestos
99%
Lead: @ pH 6.5
0.010 mg/L
Lead: @ pH 8.5
0.010 mg/L
Lindane
0.0002 mg/L
Toxaphene
0.003 mg/L
Atrazine
0.003 mg/L
2,4 - D
0.07 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Use replacement filter P4RFWB, part #W10295370.
2011 suggested retail price of $39.99 U.S.A./$49.99 Canada.
Prices are subject to change without notice.
Style 1 – When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter indicator
reads "REPLACE," it is recommended that you replace the filter.
Style 2 – When the filter indicator changes from green to yellow,
order a new filter. When the indicator changes from yellow to red,
it is recommended that you replace the filter.
Style 3 – When the filter indicator reads 10%, order a new filter.
When the indicator reads 0%, it is recommended that you
replace the filter.
Style 4 – Press FILTER to check the status of your water filter. If
the filter indicator light is yellow, order a new filter. If the filter
indicator light is red, it is recommended that you replace the filter.
After changing the water filter, flush the water system. See
"Water and Ice Dispensers" or "Water Dispenser."
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
*
Class I particle size: >0.5 to <1 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
†
Based on the use of Cryptosporidium parvum oocysts
††
Fibers greater than 10 um in length
® NSF is a registered trademark of NSF International.
12
PERFORMANCE DATA SHEET
Water Filtration System
Model P5WB2L/P4RFWB Capacity 200 Gallons (757 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, and Particulate
Class I*; and against NSF/ANSI Standard 53 for the reduction of Live
Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine, and 2,4 - D.
Average
Influent
2.0 mg/L
7,300,000 #/mL
Average
Influent
160,000/L
87 MFL
0.160 mg/L
0.140 mg/L
0.0019 mg/L
0.014 mg/L
0.0094 mg/L
0.220 mg/L
Influent Challenge
Concentration
2.0 mg/L ± 10%
At least 10,000 particles/mL
Influent Challenge
Concentration
50,000/L min.
7
8
††
10
to 10
fibers/L
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.002 mg/L ± 10%
0.015 mg/L ± 10%
0.009 mg/L ± 10%
0.210 mg/L ± 10%
The water system must be installed in compliance with state and
local laws and regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Refer to the "Warranty" section for the Manufacturer's name,
address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Maximum
Minimum %
Effluent
Reduction
0.20 mg/L
97
**
75,000 #/mL
99
Maximum
Minimum %
Effluent
Reduction
54/L
†
99.97
0.17 MFL
99
0.001 mg/L
99.4
0.005 mg/L
98.6
0.00002 mg/L
98.9
0.001 mg/L
93
0.0005 mg/L
94.5
0.028 mg/L
87.5
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi
Average %
Reduction
97.2
99.4
Average %
Reduction
99.99
99
99.4
98.6
99
93
94.7
96.1