D
efi nitions
POLLUTION - addition of foreign matter, solid, liquid, or gaseous (ionized gases), that may produce a
reduction of dielectric strength or surface resistivity.
•
POLLUTION DEGREE 2 - only non-conductive pollution occurs except that occasionally a
temporary conductivity caused by condensation is expected.
MEASUREMENT CATEGORY - Classifi cation of testing and measuring circuits according to the
types of mains circuits to which they are intended to be connected.
•
MEASUREMENT CATEGORY II (CAT II) - measuring circuits connected directly to utilization
points of the low-voltage mains installation.
•
MEASUREMENT CATEGORY III (CAT III) - measuring circuits connected to the distribution
part of the building's low-voltage mains installation.
•
MEASUREMENT CATEGORY IV (CAT IV) - measuring circuits connected at the source of
the building's low-voltage mains installation
•
The measurement category of a combination of fuse adapter with a test lead, probe, or other
accessory is the lower of assembled products
Service
If you have a need for technical or sales support, please contact us:
450986-001 Rev. A
22820 Savi Ranch Parkway
Yorba Linda, CA 92887
800-572-1028 or 714-221-9330
caltestelectronics.com
.