6. Replace strain relief (with power cord inserted) back into the
terminal block cover. Do not tighten strain relief nut.
A
B
C
D
A. Terminal block cover
B. Strain relief
C. Strain relief nut
D. Power cord
7. Now complete installation following instructions for your type
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has:
And you will be
connecting to:
4-wire receptacle
A UL listed,
(NEMA Type 14-30R)
120/240 volt
minimum,
30 amp, dryer
power supply
cord
4-wire direct
A fused
disconnect or
circuit breaker
box
5"
(12.7 cm)
3-wire receptacle
A UL listed,
(NEMA type 10-30R)
120/240 volt
minimum,
30 amp, dryer
power supply
cord
3-wire direct
A fused
disconnect or
circuit breaker
box
8
4-wire connection: Power supply cord
1. Locate the neutral grounding wire (green with yellow stripes)
Go to Section
4-wire connection:
2. Connect ground wire (green or bare) of power supply cord to
Power supply cord
3. Connect neutral wire (white or center wire) of power supply
4-wire connection:
Direct Wire
3-wire connection:
Power supply cord
3-wire connection:
4. Connect the other wires to outer terminal block screws.
Direct Wire
5. Replace the terminal block cover on the back of the dryer.
6. Tighten strain relief nut.
B
A
D
C
A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug
C. Ground prong
D. Neutral prong
E. Spade terminals with upturned ends
F. Ring terminals
inside the dryer cabinet, behind the external ground
conductor screw. Remove this wire.
A
A. Remove neutral grounding wire
(green with yellow stripes)
external ground conductor screw. Tighten screw.
cord under center screw of the terminal block.
B
A
A. Neutral wire (white or center wire)
B. Center terminal block screw
C. External ground conductor screw
D. Ground wire (green or bare) of power supply cord
Tighten screws.
E
F
C
D