Whirlpool 29" Kurulum Talimatları Kılavuzu - Sayfa 9
Kurutucu Whirlpool 29" için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. Whirlpool 29" 22 sayfaları. Dryer
Ayrıca Whirlpool 29" için: Kurulum Talimatları Kılavuzu (48 sayfalar)
Option 1 (Recommended Method)
Flexible stainless steel gas connector:
If local codes permit, use a new exible stainless steel gas
connector (Design Certi ed by the American Gas Association
or CSA International) to connect your dryer to the rigid gas
supply line. Use an elbow and a 3/8" are x 3/8" NPT adapter
tting between the stainless steel gas connector and the
dryer gas pipe, as needed to prevent kinking.
Option 2 (Alternate Method)
Approved aluminum or copper tubing:
Lengths over 20 ft. (6.1 m) can use 3/8" approved tubing
(if codes and gas supplier permit).
If you are using Natural Gas, do not use copper tubing.
3/8" are x 3/8" NPT adapter tting between dryer pipe and
3/8" approved tubing.
Lengths over 20 ft. (6.1 m) should use larger tubing and a
different size adapter tting.
If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length
of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe joint compounds that resist the action of LP
gas must be used. Do not use TEFLON
Dryer gas pipe
The gas pipe that comes out through the rear of your dryer
has a 3/8" male pipe thread.
29" Wide Model
A
A. 3/8" NPT dryer pipe
27" Wide Model
3
*5
/
"
4
(159 mm)
A. 3/8" NPT dryer pipe
Burner input requirements
Elevations up to 10,000 ft. (3,048 m):
The design of this dryer is certi ed by CSA International for
use at altitudes up to 10,000 ft. (3,048 m), above sea level at
the B.T.U. rating indicated on the model/serial number plate.
Burner input adjustments are not required when the dryer is
operated up to this elevation.
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
®†
tape.
1¼"
(32 mm)
9¼"
(235 mm)
A
1
"
1
/
2
(38 mm)
Elevations above 10,000 ft. (3,048 m):
When installed above 10,000 ft. (3,048 m) a 4% reduction
of the burner B.T.U. rating shown on the model/serial
number plate is required for each 1,000 ft. (305 m)
increase in elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
1/2 psi.
Electrical Requirements
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate circuit
serving only this dryer be provided.
GROUNDING INSTRUCTIONS
WARNING:
SAVE THESE INSTRUCTIONS
9