Whirlpool CABRIO WGD8200YW0 Kurulum Talimatları Kılavuzu - Sayfa 10
Kurutucu Whirlpool CABRIO WGD8200YW0 için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. Whirlpool CABRIO WGD8200YW0 36 sayfaları. Gas dryer
Ayrıca Whirlpool CABRIO WGD8200YW0 için: Kullanım ve Bakım Kılavuzu (36 sayfalar)
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer's instructions.
A
A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase. Contact your local dealer.
Over-the-Top Installation:
■
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent
■
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch
Part Number 4396011 - 18" (460 mm) to 29" (737 mm)
mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1270 mm)
mismatch
Special provisions for mobile homes:
Exhaust vent must be securely fastened to a noncombustible
portion of mobile home and must not terminate beneath the
mobile home. Terminate exhaust vent outside.
Moblie Home Exhaust installation
10
Determine vent path:
Select route that will provide straightest and most direct
■
path outdoors.
Plan installation to use fewest number of elbows and turns.
■
When using elbows or making turns, allow as much room
■
as possible.
Bend vent gradually to avoid kinking.
■
Use as few 90° turns as possible.
■
Determine vent length and elbows needed for best
drying performance:
B
Use following Vent System Chart to determine type of vent
■
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified
in Vent System Chart. Exhaust systems longer than those
specified will:
Shorten life of dryer.
■
Reduce performance, resulting in longer drying times
■
and increased energy usage.
The Vent System Chart provides venting requirements that
will help achieve best drying performance.
Number of
90° elbows
NOTE: Bottom exhaust installations have a 90° turn inside the
dryer. To determine maximum exhaust length, add one 90° turn
to the chart.
INSTALL VENT SYSTEM
1.
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
Vent System Chart
Type
Box/louvered
of vent
0
Rigid metal
64 ft. (20 m)
1
Rigid metal
54 ft. (16.5 m)
2
Rigid metal
44 ft. (13.4 m)
3
Rigid metal
35 ft. (10.7 m)
4
27 ft. (8.2 m)
Rigid metal
Install exhaust hood
(305 mm)
Angled
hoods
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
12" min.
(305 mm)
12" min.