Whirlpool Centennial MEDC700 Kurulum Talimatları Kılavuzu
3. Connect neutral ground wire (E) and the neutral wire (C)
(white or center wire) of power supply cord under center,
silver-colored terminal block screw (B). Tighten screw.
4. Connect ground wire (F) (green or bare) of power supply cord
to external ground conductor screw (A). Tighten screw.
A
F
5. Connect the other wires to outer terminal block screws.
Tighten screws.
6. Tighten strain relief screws.
7. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
8. You have completed your electrical connection. Now go
to "Venting Requirements."
8
B
E
C
3-wire connection: Power supply cord
use where local codes permit connecting cabinet-ground
conductor to neutral wire.
B
A
C
A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with upturned ends
E. 3/4" (19 mm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
1. Loosen or remove center, silver-colored terminal block
screw (B).
2. Connect neutral wire (C) (white or center wire) of power supply
cord to the center, silver-colored terminal screw (B)
of the terminal block. Tighten screw.
3. Connect the other wires to outer terminal block screws.
Tighten screws.
4. Tighten strain relief screws.
E
D
F
G
B
B
C