FirePro ST522E Kullanıcı Kılavuzu - Sayfa 2
Duman Alarmı FirePro ST522E için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. FirePro ST522E 5 sayfaları.
respond to it to reduce the risk of damage, injury, or death
that may result from fire. If a household member is hard
of hearing, install special smoke alarm devices with lights
or vibrating devices to alert occupants.
7: Smoke alarm devices can only sound their alarms when
they detect smoke or detect combustion particles in the
air. They do not sense heat, flame, or gas. This smoke
alarm device is designed to give audible warning of a
developing fire. However, many fires are fast - burning,
explosive, or intentional, and others are caused by
carelessness or safety hazards. In this instance, smoke
may not make the smoke alarm sound QUICKLY
ENOUGH to ensure safe escape.
8: Smoke alarm devices have limitations. This smoke alarm
device is not foolproof and is not warranted to protect
lives or property from fire. Smoke alarm devices are not a
substitute for insurance. Homeowners and renters should
insure their lives and property. In addition, it is possible
for the smoke alarm device to fail at any time. For this
reason, you must test the smoke alarm device weekly and
replace unit every 10 years.
Do Not Install Smoke alarm devices in the
following places:
1: Near appliances or areas where normal combustion
regularly occurs (kitchens, near furnaces, hot water
heaters). Use a specialised smoke alarm device with
unwanted alarm control for these areas.
2: In areas with high humidity, like bathrooms or areas near
dishwashers or washing machines. Install at least 3m
away from these areas.
3: Near air returns or heating and cooling supply vents.
Install at least 1 metre away from these areas. The air
could blow smoke away from the detector, interrupting its
alarm.
4: In rooms where temperatures may fall below 5℃ or
rise above 45℃, or in humidity higher than 85%. These
conditions will reduce battery life or cause a fault alarm.
5: In extremely dusty, dirty, or insect-infested areas.
Particles interfere with smoke alarm device operation.
Operation:
Testing
Test the unit to ensure proper operation by pressing the test
button. This will sound the alarm if the electronic circuitry,
bracket is mounted, horn and battery are working. If no
alarm sounds, there is a defective battery or other failure,
you can refer to "Trouble shooting" section for solution.
DO NOT use an open flame to test your alarm, you could
damage the alarm or ignite combustible materials and start
a fire.
CAUTION: Due to the loudness (85 decibels) of the alarm,
always stand an arms-length away from the unit when
testing.
Test the alarm weekly to ensure proper operation. Erratic or
low sound coming from your alarm may indicate a defective
alarm, you can refer to "Trouble shooting" section for
solution.
NOTE: WEEKLY TESTING IS REQUIRED.
LED indicators
Red LED-Flashing once every 40 seconds: indicates that the
smoke alarm device is operating properly.
Red LED-Flashing: when the test button is pressed, or when
the smoke alarm device sense particles of combustion and
goes into alarm (constant pulsating sound), the red LED
will flash once per second. The flashing LED and pulsating
alarm will continue until the air is cleared or release test
button.
Red LED-Alarm silencer (Hush mode) indication: The red
LED will flash once every 8 seconds, indicating the smoke
alarm device is in the alarm silence (Hush) mode.
Low battery indication - An intermittent "chirp" with red
LED flashes once every 40 seconds: indicates that the
battery is low. You may press the test button to pause alarm
for 10 hours, but it will reset automatically after 10 hours.
Fault indication - The alarm chirp occurs every 40 seconds.
NOTE: When the units chirp once every 40 seconds,
you can press the test button temporarily for pausing this
warning tone for 10 hours, it can still normally detect smoke
during this period, it only removes nuisance warning tone.
You can refer to "Trouble shooting" for a solution, if there
are still failures, you MUST replace it with a new alarm
at once or contact you retailer during warranty.
Alarm silence (silence mode)
Whilst the unit is alarming, if you push the test button,
it will stop the unit alarming for approx 10 minutes. The
red LED will flash once every 8 seconds, it indicates the
smoke alarm device is running in silence mode. Smoke
alarm devices are designed to minimise nuisance alarms.
Combustion particles from cooking may set off the alarm
if the alarm is located close to the cooking area. Large
quantities of combustible particles are generated from spills
or when grilling/frying. Using the fan on a range hood
that vents to outside (non-recirculating type) will also help
remove these combustible particles from the kitchen. The
alarm silence (test button) is extremely useful in a kitchen
area or other areas prone to nuisance alarms. The silence
feature is to be used only when a known alarm condition,
such as smoke from cooking activates the alarm.
The smoke alarm device is desensitised by pushing the
- 2 -
Document NO.: FP522V-001 2020.02.18 Version: A