Whirlpool 24" (58 CM) Kurulum ve Kullanım Kılavuzu - Sayfa 8

Havalandırma Davlumbazı Whirlpool 24" (58 CM) için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. Whirlpool 24" (58 CM) 24 sayfaları. 24" (58 cm), 30" (76.2 cm), 36" (91.4 cm) range hood

2. To wire through top:
Mark a line 7½" (19 cm) from the right of the centerline on the
underside of the cabinet. Mark the point on this line that is
2" (5 cm) from back wall. Drill a 1¼" (3 cm) diameter hole
through the cabinet at this point.
To wire through rear wall:
Mark a line 7½" (19 cm) from the right of the centerline on the
wall. Mark the point on this line that is 65¼" (165.7 cm) from
the floor [or ¾" (1.9 cm) from underside of cabinet]. Drill a
1¼" (3 cm) diameter hole through wall at this point.
65 / "
(165.7 cm)
to floor
Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm)
Rectangular Vent Sytem
Roof Venting
To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangular cutout on
the underside of cabinet top and bottom:
1. Mark lines 1½" (3.8 cm) and 5½" (14 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4. Repeat steps 1-3 for the underside of the top of the cabinet
Cabinet cutouts
*From wall, not cabinet frame
8
2" (5.1 cm)
7
"
from wall,
(19 cm)
not cabinet
frame
Centerline
" (1.9 cm)
7 "
(19 cm)
Centerline
*1 / " (3.8 cm)
*5 / "
5 / "
(14 cm)
(13.3 cm)
5 / "
(13.3 cm)
Wall Venting
To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangle in the wall:
1. Make 2 lines by measuring from floor 65 " (167.3 cm) and
62 " (158.4 cm) or
" (3.2 mm) and 3 " (9.2 cm) down from
underside of cabinet and mark on the centerline on the back
wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
Cabinet
front
"
(3.2 mm)
"
(9.2 cm)
Style 2 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm)
Rectangular Vent to 6" (15.2 cm) Round Vent Transition
Roof Venting
To make a 4" x 10½" (10.2 x 26.7 cm) rectangular cutout on the
underside of cabinet bottom:
1. Mark lines 1½" (3.8 cm) and 5½" (14 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
*5 / "
(14 cm)
*From wall, not cabinet frame
To make a 6 " (15.9 cm) circle on the underside of the cabinet
top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 4 " (12.1 cm) from the back wall on the underside
of the top of cabinet.
3. Draw a circle using a compass or 6 " (15.9 cm) circle
template.
Centerline
5 "
(13.3 cm)
*1 / " (3.8 cm)
5 / "
(13.3 cm)
5 / "
(13.3 cm)