Whirlpool GZ8336XLS Kurulum Talimatları ve Kullanım & Bakım Kılavuzu - Sayfa 5

Havalandırma Davlumbazı Whirlpool GZ8336XLS için çevrimiçi göz atın veya pdf Kurulum Talimatları ve Kullanım & Bakım Kılavuzu indirin. Whirlpool GZ8336XLS 20 sayfaları. Gz8330 series, gz8336 series 30" (76.2 cm) and 36" (91.4 cm) convertible range hood
Ayrıca Whirlpool GZ8336XLS için: Boyut Kılavuzu (1 sayfalar)

Whirlpool GZ8336XLS Kurulum Talimatları ve Kullanım & Bakım Kılavuzu
4.
From the diagrams below,
select the diagram for your
installation.
Vented installations: Cut the vent
system and electrical wiring
access holes as required. Either
wiring hole can be used.
Non-vented installations: Cut only
the one 1-1/4" (3.2 cm) dia. wiring
access hole required. If wiring
through the top, use location
shown in VERTICAL vent systems.
If wiring through the back, use
location shown in HORIZONTAL
vent system.
6-1/4"
(15.9 cm)
centerline
1-1/4"
wall
5-1/8"
1-3/8"
(3.2 cm)
(13.0 cm)
(3.5 cm)
dia. hole
3-1/4" x 10" (8.3 x 25.4 cm)
RECTANGULAR VERTICAL
vent system
centerline
1-1/4" (3.2 cm)
cabinet
dia. hole
front
1/8"
(3.2 mm)
3-7/8"
6-1/4"
(9.8 cm)
(15.9 cm)
3-1/4" x 10" (8.3 x 25.4 cm)
HORIZONTAL vent system
Prepare and install

the hood

WARNING
Excessive Weight Hazard
Use two or more people to move
and install range hood.
Failure to do so can result in
back or other injury.
For Steps 5 through 10, refer to
Figure 3.
5.
Set hood upside down on a
protective covering such as
cardboard or large towel.
7-1/2"
screws
(19.1 cm)
2-1/8"
(5.4 cm)
6.
Remove bottom cover
screws and bottom cover.
7.
Remove filters.
8.
Remove wiring box cover
and screws.
3/4"
(19 mm)
9.
7-1/2"
To make the hood lighter
(19.1 cm)
and easier to install, it is
recommended that the blower
assembly be removed.
To remove:
a) Disconnect blower wiring
plug.
b) Loosen, but do not remove,
knurled nuts on mounting
rods. Slip rods out of blower
mounting brackets.
Important: Do not grasp blower
by blower wheels. Wheels may
be damaged.
c) Lift blower out and set aside.
10.
Remove light lens.
Squeeze sides of lens toward
center to free lens tabs and lift
lens out.
11.
Depending on your
installation, remove either back or
top wiring knockout.
screws
bottom cover
filters
wiring box
cover
blower
wheel
Figure 3
light
lens
knurled
nut
mounting
rod
blower
assembly
protective
cover
For vented installations, go to
Step 12a.
For non-vented installations,
go to Step 13.
12a.
Depending on your
installation, remove either back or
top vent knockout.
vertical
vent
horizontal
vent
black screws
hinge pin
12b.
Attach the
damper/vent connector to the
hood. Use the two black sheet
metal screws provided in the
parts bag. Note: If wall cap is
directly behind vent connector,
the dampers in the connector and
wall cap MUST NOT interfere
with each other. Remove the vent
connector damper if they
interfere.
mounting
bracket
black
screws
hinge pin
vent
knockouts
5