Venting requirements
Horizontal wall venting
Now start...
Vented models only
Non-vented models cannot be converted to vent.
With range hood in kitchen.
Slide cardboard
or hardboard
under range
before moving range across floor to prevent
damaging
floor covering.
Cover countertop,
cooktop or set-in range
with a thick, protective
covering to prevent
damaging
countertop.
Venting
system must terminate
to the
outside.
3-l/4"
x 10"
through
the wail
Do not terminate
the duct in an attic or
other enclosed
space.
Do not use four-inch
laundry-type
wall
caps.
Do not use plastic
duct.
Duct needed for installation
is not included.
Backdraft damper supplied with product
must be used. If roof or wall cap has a
damper, do not use damper supplied with
hood. Use metal duct only. Rigid metal duct
is recommended.
Determine
which
outside
venting
method
you need to use.
The length
of the duct and number
of
elbows
should be kept to a minimum
to
provide
efficient
performance.
The size of
the duct should
be uniform.
Do Not install
two elbows
together.
Use duct tape to seal
all joints in the duct system. Duct can
terminate
either through
the roof or wall.
Use caulking
to seal exterior
wall or roof
opening
around
exhaust
hood. For the most
efficient
and quiet operation,
it is
recommended
that the range
hood
be
vented
vertically
through
the roof using 7"
round duct.
Figures l-4 show common
venting
methods
and what types of materials
are needed.
wail cap
4
24!l
4
1
W Disconnect
and move freestanding
range from cabinet
opening
to provide
easier access to upper
cabinet
and rear
wall. Put a thick, protective
covering
over
cooktop,
set-in range or countertop
to
protect
from damage
or dirt.
2
W If your range hood
is a vented-only
model, determine
which
venting
method
(roof or wall venting)
you need to use.
Figure 3
roof cao
7" min. diameter
7" min. diameter
round duct
round duct
eibows~--~--i-~i:::i.~
If your range hood is a non-vented-
(recirculating)
only model, go to Step 3a,
Panel D.
3-l/4"
x 10" to round
3-l/4"
x 10" to round
duct transition
duct transition
Figure 4
To install a
vented-only
model
fnstalation:
Recommended
duct length
Use 3-l /4" x lo" or 7" duct with a maximum
length
of 26 feet for duct system. For best
performance,
use no more than three 90"
elbows. To calculate
the length
of system
you need, add the equivalent
feet for each
duct piece
used in the system. See the
following
examples.
3- l/4" x lo" duct system
Vertical roof venting
roof cap
,
/
7" round vent
\
I
knockGuts
knockouts
W Remove
knockout
from the wirina
3-l 14" x 10"
eibow ~~KiI13e~
L
2
h. 1 - 90" elbow
= 5
ft.
1
8 feet straight
= 8
ft.
1 - wall cap
= 0
ft.
Length of 3-l/4"
x
lo" system
=13
ft.
66"
d
\'p7"'
--. .:
-
opening
(top or rear) to be used.
For rectangular
venting,
remove
only the
3-l /4" x lo" rectangular
opening
knockout
for the venting
method
(roof or wall) you
Figure 1
1
Recommended
standard fittings
have selected.
Vertical roof venting
roof cap
/
terminal
box
cover
3-114" x 10" 90"
3-l/4"
x 10" fiat
3-l/4"
x 10" wail
elbow = 5 ft.
elbow = 12 ft.
cap = 0 ft.
3-l/4"
x lo"
through
the roof
i+Q,
t
r
66"
7" duct system
9VeibMF6ft.-q,FP
'3-l/4"
x lo"
damper
4
W Remove
terminal
box cover from
L
Maximum length
= 26
feet
1 - transition
= 4.5 ft.
range hood.
3-l/i'x
lo"
to 7"
transition
2 - 90" elbows
1 - wall cap
8 feet straight
=lO
ft.
= 0
ft.
= 8
ft.
Excessive Weight Hazard
Use two or more people to move and
install range hood.
Failure to follow this instruction
can
result in back or other injury.
Length of 7" system
= 22.5 ft.
Figure 2
Recommended
standard fittings
keyhole
slot
front
of hood
w
W Lift the ranae
hood
into final
3-114" x 10" to 7"
90" elbow = 5 ft.
90" elbow = 5 ft.
I
/
5
45" elbow = 2.5 ft.
7" wail cap = 0 ft.
position
and center.
Mark on the underside
of cabinet
the location
of the four keyhole
mounting
slots. Set range hood aside on a
protected
surface.
Panel B