Wall Venting
To make a 4" x 101/2 '' (10.2 cm x 26.7 cm) rectangle in the wall:
1. Make 2 lines by measuring from floor 657/8 '' (167.3 cm) and
62%" (158.4 cm) or 1/8"(3.2 mm) and 3%" (9.2 cm) down from
underside of cabinet and mark on the centerline on the back
wall.
2. Mark lines 5W' (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
(3.2 ram)
ii
3%"
V_"
(9.2 sin)
i
(13.3 sin)
Style 2 - Cut Openings for 7" (17.8 cm) Round Vent
System
Roof Venting
To make a 71/4 '' (18.4 cm) circle on the underside of the cabinet
top and bottom:
1. Mark a centerline on the underside of the cabinet bottom.
2. Mark a line 5" (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Draw a circle using a compass or 71/4 '' (18.4 cm) circle
template.
4. Use saber or keyhole saw to cut a 71/4 '' (18.4 cm) diameter
opening.
5. Repeat steps 1-4 for the underside of the top of the cabinet.
(19.4 cm) diam.
cabinet
cutouts
Style 3 - Cut Openings for 31/4'' x 10" (8.3 x 25.4 cm)
Rectangular
Vent to 7" (17.8 cm) Round Vent Transition
Roof Venting
To make a 4" x 101/2 '' (10.2 x 26.7 cm) rectangular cutout on the
underside of cabinet bottom:
1. Mark lines 11/2 '' (3.8 cm) and 51/2 '' (14 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5W' (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
(14 cm)
/
5V4"
(13.3 cm)
*From wall, not cabinet
frame
To make a 71/4'' (1 8.4 cm) circle on the underside of the cabinet
top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 5" (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Draw a circle using a compass or 71/4 '' (18.4 cm) circle
template.
4. Use saber or keyhole saw to cut a 71/4 '' (18.4 cm) diameter
opening.
7V4" (18.4 crn} diam.
*From wail
not
cabinet
frame
Cabinet
cutouts
Install Vent System
1.
2.
Install vent through the vent opening in upper cabinet or wall.
Complete venting system according to the selected venting
method. See "Venting Requirements"
section.
Use caulking to seal exterior wall or roof opening around the
cap.
Remove terminal box cover. Depending on your installation,
remove either back or top wiring knockout.
A. Terminal box cover