Whirlpool WVI30336LS Kurulum Talimatları ve Kullanım & Bakım Kılavuzu - Sayfa 12

Havalandırma Davlumbazı Whirlpool WVI30336LS için çevrimiçi göz atın veya pdf Kurulum Talimatları ve Kullanım & Bakım Kılavuzu indirin. Whirlpool WVI30336LS 32 sayfaları. 30" and 36" (76.2 and 91.4 cm) island-mount canopy range hood

Whirlpool WVI30336LS Kurulum Talimatları ve Kullanım & Bakım Kılavuzu
6.
Install the lower duct cover (rear) to the range hood canopy.
Spread the lower duct cover opening slightly and position it
over the upper duct cover. Set the lower duct cover in place.
Position so the flanges of the lower duct cover set into the
flanges of the upper duct cover. Make sure the front and rear
lower duct covers mate properly.
NOTE: When assembling the rear lower duct cover to the
front lower duct cover, the flange (both sides) must be placed
over the plastic clip to secure the lower duct covers together
at the bottom.
A
B
C
A. Lower duct cover (rear)
B. Plastic clips
C. Lower duct covers
D. Upper duct covers
7. Secure the lower duct covers together at the top using 2
plastic clips. Use one plastic clip on each side.
A
A. Plastic clips (2)
B. Lower duct covers top clip area
12
D
B
8. Secure the lower duct cover to the range hood canopy using
4 - 4.2 x 8 mm screws.

Complete Installation

1. For non-vented (recirculating) installations only, install
charcoal filters over metal grease filter. See the "Range
Hood Care" section.
2. Install metal filters. See the "Range Hood Care" section.
3. Check the operation of the range hood blower and light.
See the "Range Hood Use" section.
If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.