NOTES:
Depending on your model, determine which venting method
■
to use: roof, wall or non-vented (recirculating).
It is recommended that the vent system be installed before
■
the range hood is installed. Go to "Venting System" in the
"Installation Requirements" section if you need assistance.
Before making cutouts, make sure there is proper clearance
■
within the ceiling or wall for the vent system.
1. Disconnect power
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
2. Mark hole locations
Align the exterior edge of the mounting brackets with the exterior
edges of the upper cabinet.
IMPORTANT: The brackets should touch the upper cabinet.
With a pencil, mark the upper holes on the brackets.
3. Install brackets
INSTALLATION INSTRUCTION
Using a #2 Phillips screwdriver, install the drywall anchors.
■
Using #8-18 x 1" (4.2 x 25 mm) flat-head #2 Phillips screws,
■
install the mounting brackets using the upper holes.
NOTE: For installations to a surface other than drywall, it
is recommended that a qualified contractor determine the
anchoring method.
4. Remove grease filters
Remove the two filter security screws and put them aside.
■
Press the filter latch to release the grease filters.
■
Remove each grease filter.
■
5. Prepare Range Hood
Set the range hood on its back on a covered surface.
■
Using a #2 Phillips screwdriver, remove the rectangular
■
damper attached with 3.5 x 9.5 mm screws.
Using a #2 Phillips screwdriver, remove the electrical box
■
cover.
Using a flat-blade screwdriver, remove the appropriate power
■
supply knockout.
7