For info call: 1 . 888 . 769 . 3444
The fire table is for outdoor use only. DO NOT install or use this fire table inside a building, garage, or any other
enclosed area including recreational vehicles and/or boats. This unit must be installed in such a manner that
proper air ventilation is maintained without obstruction at all times and during all weather conditions.
Before installing this fire table, check "Minimum Clearance to Combustibles" on page 2. MINIMUM CLEARANCES
must be maintained when you install this fire table. THERE MUST BE AT LEAST 60" from the center of the burner
to any combustible sidewall and 72" from any overhang.
Ensure that the fire table installed in such a manner that the vent opening at the base of unit remains obstacle-free
at all times and during all weather conditions.
DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR EXCEEDS THE
MAXIMUM.
FOR NATURAL GAS: The minimum inlet gas supply pressure for purposes of input adjustment is 3.5 inches
water column and maximum inlet gas supply pressure is 10.5 inches water column. FOR PROPANE: The mini-
mum inlet gas supply pressure for purposes of input adjustment is 8 inches water column and the maximum inlet
gas supply pressure is 11 inches water column. A standard 20 lb. portable propane tank can be connected to the
table. DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRES-
SURE IS EXCEEDED.
Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr). Undue
pressure loss will occur if the pipe is too small or the run is too long.
For use with a fixed-fuel piping system and equipped with an appliance gas pressure regulator, the required
manifold pressure in inches water column.
The fire table and its main gas valve must be disconnected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of ½ psig. This is accomplished by closing the gas supply line
valve, as required by NFPA 54, section 5-54.
GAS SUPPLY PLUMBING REQUIREMENTS: Apply only joint compounds that are resistant to all gasses on all
male pipe fittings. Make sure to tighten every joint securely. Do not use pipe joint compound to connect flare fittings.
The fire table must be isolated from the gas supply piping system by closing its equipment shut-off valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig.
For installations at elevations above 2,000 ft., contact your local dealer or gas supplier before installing as input
ratings should be reduced approximately 4% for each 1,000 ft. above sea level. Refer to the National Fuel Gas
Code. Contact the factory for the required orifice.
INSTALLER NOTE: This unit should be installed so that it can be removed at a later date for service.
SAFETY NOTE: An external on/off valve in the gas line is required for safety when your fire table is not in
use. It also provides for convenient maintenance and repair.
Owner's Manual

IMPORTANT SAFETY INFORMATION

INSTALLATION AND PREPARATION SAFETY GUIDELINES
Page 3