CALEFFI SATK40 Series Kurulum, Devreye Alma ve Bakım Talimatları - Sayfa 2

Kontrol Ünitesi CALEFFI SATK40 Series için çevrimiçi göz atın veya pdf Kurulum, Devreye Alma ve Bakım Talimatları indirin. CALEFFI SATK40 Series 12 sayfaları. Wall-mounted compact indirect hiu - dhw production in storage cylinder

CALEFFI SATK40 Series Kurulum, Devreye Alma ve Bakım Talimatları

SAFETY INSTRUCTIONS

W RNINGS
These instructions must be read and understood before installing and maintaining the device.
C UTION! F ILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN
1 The device must be installed, commissioned and maintained by qualified technical personnel in accordance with national regulations and/or relevant local requirements.
2 If the device is not installed, commissioned and maintained correctly in accordance with the instructions provided in this manual, it may not work properly and may
endanger the user.
3 Clean the pipes of any particles, rust, incrustations, limescale, welding slag and any other contaminants. The hydraulic circuit must be clean.
4 Make sure that all connection fittings are watertight.
5 When connecting water pipes, make sure that threaded connections are not mechanically overstressed. Over time this could result in breakage, with water leaks
causing damage and/or injury.
6 Water temperatures higher than 50°C may cause severe burns. When installing, commissioning and maintaining the device, take the necessary precautions so
that these temperatures will not be hazardous for people.
7 In the case of particularly hard or impure water, adequate water filtration and treatment must be assured upstream from the device, in accordance with current
legislation. Otherwise the device may be damaged and will not work properly.
8 Any use of the device other than its intended use is prohibited.
9 Any combination of the device with other system components must be made taking the operational characteristics of both units into consideration.
10 An incorrect coupling could compromise operation of the device and/or system.
IMPORTANT: Risk of electric shock. Live parts. Shut off the electric supply before opening the device box.
1 During installation and maintenance operations, always avoid direct contact with live or potentially hazardous parts.
2 The device must not be exposed to water drops or humidity, direct sunlight, the elements, heat sources or high intensity electromagnetic fields. This device cannot
be used in areas at risk of explosion or fire.
3 The device must be connected to an independent two-pole switch. If work has to be done on the device, cut off the electric supply first. Do not use devices with
automatic or time reset, or which may be reset accidentally.
4 Use suitable automatic protection devices in accordance with the electrical characteristics of the region in which the device is installed and in compliance with
current legislation.
5 The device must always be earthed before it is connected to the electric supply. If the device has to be removed, always disconnect the earth connection after
disconnecting the electric supply conductors. Check that the earth connection has been made to the highest of standards under applicable legislation.
6 Electrical installation must only be carried out by a qualified technician, in accordance with legal requirements.
7 The device does not contain asbestos or mercury.
8 The device is not designed for use by persons of reduced mental, physical or sensory capacity (including children) or persons lacking experience, unless they are
supervised or instructed in use of the device by a person responsible for their personal safety.
LE VE THIS M NU L
S
M NUF CTURER RESERVES THE RIGHT TO CE SE PRODUCTION
NECESS RY WITHOUT THE OBLIG TION OF PRIOR NOTICE.
NOTES:
1 Install water hammer arresters to compensate for any overpressure in the domestic water circuit;
2 In the presence of hot water recirculation or if a non-return valve is fitted into the domestic cold water inlet, provision must be made to accommodate the expansion
of the water contained within the system and the heat interface unit;
3 All hydraulic connections must be checked before pressurising the system. Vibration during transport may cause the connections to become loose. DO NOT APPLY
EXCESSIVE TIGHTENING TORQUE otherwise the components may be damaged.
For the updated version of the technical documentation refer to www.caleffi.com
Key to symbols
Primary circuit flow
Primary circuit return
D
REFERENCE GUIDE FOR THE USER. DISPOSE OF IN
High temperature circuit flow
High temperature circuit return
Low temperature circuit flow
Low temperature circuit return
CCORD NCE WITH LOC L REGUL TIONS. THE
T
NY TIME
ND TO M KE
P
2
S FETY H Z RD!
NY CH NGES DEEMED USEFUL OR
Storage flow
Storage return
M
Domestic cold water inlet
(filling)