7 Momentarily press the "POP" buttons to flash the strobes.
RECORD/PLAYBACK FUNCTIONS
To ready the Popper 6X for recording, Press the "Record" button once. The record button
will light solid.
To begin recording, press the "Record" button again. The "Record" button will blink to
indicate that recording is in progress.
Press any sequence of flash buttons, at the desired timing, and a sequence will be
recorded.
To end a recording, Press the "Record" button a 3rd time. The button will go dark to
indicate that it is no longer recording.
To playback, simply press the "Play" button. The entire recorded sequence will be played
back. Pressing the "Pause" button once will suspend playback, and pressing it again will
resume, where it left off. Pressing the "reset" button will reset playback to the beginning of
the sequence.
Pressing the 'Loop" during playback will continue to loop the sequence endlessly, until
either the "Pause" or "Loop" button is pressed again.
The sequence recorded in memory will remain in memory until it is erased, when a new
sequence is recorded, even after a power down or battery change.
Notes
You may daisy chain as many strobe units as you like off of any or all output connectors.
Dataflash AF 1000 units will "safety timeout" if they flash continuously over a short period
of time. The yellow LED indicator in the Dataflash AF1000 head will blink to indicte the
timeout. When this happens, the system will cool down and reset its self in 2 minutes.
The duration value (00-99) indicates a true time, in 120ths of a second. A Duration value
of 00 will indicate a flash of 1 120th of a second in duration. A Duration value of 01 will
indicate a flash of 2 120ths of a second. etc. A duration value of 04 indicates a flash of
1/24th of a second, and represents the shortest flash which will reliably expose
consistently at 24 fps. We recommend beginning testing with a Duration value around 12.
To replace 3 AAA batteries inside the unit, unscrew the 4 phillips bolts holding the end
panel in place.