Alderon Industries 7039 Kullanıcı Kılavuzu - Sayfa 7
Ölçüm Cihazları Alderon Industries 7039 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Alderon Industries 7039 16 sayfaları. Cast iron cable weight control and pump switches
Cast Iron Cable Weight - USER GUIDE
Installing Float Switch Cable (continued)
STEP 3: SECURE FLOAT SWITCH CABLE
To secure float switch cable to the cable weight, place the top half of the cable weight over the float switch cable and align the
screw holes to the bottom half of the cable weight (3A). Tighten the two screws so both halves of the cable weight are snug
against the cable (3B). Perform a pull test, if the float switch cable slips, tighten the screws until securely fastened to prevent
slipping of the cable, this will maintain an accurate activation level (control switches) or pumping range (pump switches).
3A
3B
Alderon Industries™ - Leading Edge Control Products | 7