frequency response calibration. This value is zero unless you set a measurement frequency with
the 'freq' parameter. The 'fcor' parameter is read-only, the value only can be set by changing the
'freq' parameter.
offs
The value [dB] specified with this parameter is added to the measured power before it is
displayed and compared to the fault threshold value. If 'offs' is set to zero, the power sensor
shows the power which is measured at it's input connector. The valid range for 'offs' is -99.99 to
99.99.
snr
The power sensor's serial number. This is a five digit hexadecimal number which uniquely
identifies each individual unit. 'snr' is a read-only parameter.
Floating point numbers (as for the 'thrh' and 'offs' parameters) may consist of digits, one optional decimal
point and a leading minus sign for negative numbers. The 'freq' parameter is restricted to be a positive
integer, it may consist of digits only. Malformed numbers are recognized as zero.