Yamaha CP2000 Servis Kılavuzu - Sayfa 17
Amplifikatör Yamaha CP2000 için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Yamaha CP2000 33 sayfaları. Yamaha power amplifier owner's manual
Ayrıca Yamaha CP2000 için: Kullanıcı El Kitabı (20 sayfalar), Servis Kılavuzu (33 sayfalar)
INSPECTIONS
1.
Inspection during stereo mode and parallel mode
1.1
Preparations
Input attenuator
Input terminal
Mode SW
Yamaha speaker processing
Output terminal
Others
1.2
Inspection and adjustment
1.2.1 Fan and temperature indicator
The fan shall operate when the two jumper wires inside the frame marked
FAN-C inside sheet IN are shorted. Next, the temperature indicator shall
come on when the two jumper wires inside the frame marked TM-C are
shorted. (Refer to the figure to the right for FAN-C, TM-C.)
1.2.2 Power on muting time
At t=2.5 ± 1 seconds after the power switch is turned on, the muting shall be cancelled and the protection indicator shall go off.
1.2.3 Idling current
Ground the input terminal and adjust VR101 (L ch) and VR102 (R ch) so that the CN108 (L ch) and CN107 (R ch) No. 1 and 2
terminals show DC voltage of Vb=0.5 ± 0.1 mV.
Once all inspections have been completed, re-inspect Vb and adjust so that it is Vb=0.5 ± 0.1 mV.
1.2.4 Output terminal DC voltage
Ground the input terminal and measure the Vdc (direct current voltage) of the output terminal. It shall be Vdc=0 ± 75 mV.
1.2.5 Gain
An output voltage of +24.0 ± 0.5 dBu shall be attained when 1 kHz, -10.0 dBu sine wave is input to the input terminal.
This inspection shall also be performed in the PARALLEL mode.
1.2.6 Frequency characteristics
* YAMAHA SPEAKER PROCESSING OFF:
Using 1 kHz as a standard for the output voltage, the output voltage shall be within -0.5 ± 0.5 dB at 20 kHz when 20 Hz, 1 kHz,
20 kHz, -10 B dBu sine waves are input to the input terminal.
* YAMAHA SPEAKER PROCESSING ON:
Using 1 kHz as a standard for the output voltage, with the Yamaha speaker processing off, the output voltage shall be within +
6.5 ± 1.5 dB when a 70 Hz, -10 dBu sine wave is input to the input terminal.
1.2.7 Total harmonic distortion ratio characteristics
The total harmonic distortion ration shall be THD=1 % or less when a 1 kHz high definition sine wave is input to the input terminal
and the rated output of 650 w + 650 w / 4 ohm (36.4 dBu/ch) has been attained. This inspection shall be completed within 30 seconds.
1.2.8 Channel separation load resistance 8 Ω
When the input terminal for one of the channels has attained a 1kHz, -5dBu sine wave has and that input terminal is grounded by
the introduction of 600 Ω resistance, the measured output voltage of the other channel shall by -70 dB or less, using a output voltage
with (0 dB) as the reference level.
1.2.9 Output noise level
Measure the noise level at the output terminal when the input attenuator has been set to MAX and a input terminal has been grounded
by the introduction of a 600 Ω resistance. It shall be -67 dBu or less. Next, set the input attenuator to MIN and measure. It shall be
-70 dBu or less.
All manuals and user guides at all-guides.com
MAX
Cannon connector No. 2 hot; No. 1, 3 ground
Stereo
Off
Resistance load 4 Ω, Non inductance resistor, input capacitance 500 W or more.
Unless otherwise specified, drive both channels unless otherwise specified.
<Top View>
AC
3/6
PA
AC
2/6
CP2000
IN
TM-C
FAN-C
17