ACOPOWER 3x35W Manuel - Sayfa 5

Solar panel ACOPOWER 3x35W için çevrimiçi göz atın veya pdf Manuel indirin. ACOPOWER 3x35W 7 sayfaları. 105w foldable solar panel

ACOPOWER 3x35W Manuel
common trouble-shooting
Troubles
When the modules
directly face to the sun ,the
charge indicator does not
light
Charging light fast
flashing
LED1 :Led1 fast
flashing
Load Leds slow
flashing
Load Leds fast flashing
indicator is off on
the normal charging status
www.ACOPower.com
trouble shooting
1、solar arrays'
connection open
2、solar cells connected
reverse
Voltage turn off
when battery voltage is
in overpressure,
Battery over discharge
Load power exceeds
rated power
Load :short-circuit
Input power is less than the
battery power
105W Foldable solar panel
solution
1、Check the power terminals if in correct and
good connection,
2、Controller may be damaged,change a new one
Measuring the battery voltage if it is too high,then
disconnect the modules
The controller output shut down automatically ,
indicator light in normal flash when the battery is full of
charge
Reduce some AC loads and press the button 3
seconds to recover the controller output
When short-circuit happened in the first time,
please wait 10 seconds,the system
output shall be auto restart or you can press the
button 3 seconds to get the normal output; if
short-circuit take place one after another , the system
output will return to normal only by pressing the
button 3 seconds
Measure the controller input voltage which must
be higher than the battery voltage
Power Your Green Life!