TESTING THE RF TRANSMISSION
It is important to site both the receiver units and the programmable thermostat in locations
where the RF signal cannot be interrupted.
The units operate up to a range of approximately 30 metres indoors, however, structural
characteristics of some buildings can affect the range. Thick walls, foil backed plasterboard,
and general RF interference can cause an issue.
A 30 meter radius range is generally large enough for most household applications but it is
often advisable to test the RF transmission from the intended location of the programmable
thermostat and the radiators that it is to control prior to fixing the programmer to the wall.
This can be achieved by following these steps:
1.
Press the UP button until the target temperature is a few degrees higher than the
indicated room temperature.
2.
Wait for a few seconds. The heat call indicator should appear in the bottom left part
of the LCD.
3.
Go to the receiver unit. The green LED should be illuminated.
4.
Press the DOWN button on the programmable thermostat to reduce the target
temperature to a few degrees lower than the room temperature
5.
Wait for a few seconds. The heat call indicator should disappear from the LCD. The
green LED on the receiver should now be off.
6.
If at step 3 the green LED is not illuminated, press the RESET button on the
programmable thermostat place it closer to the radiator and receiver unit.
7.
Repeat steps 1 to 5.
If a stable RF connection between the programmable thermostat and a receiver unit is not
possible, check that the receiver unit is both switched on and has a mains power connection
which is indicated by the illuminated red LED. If the red LED is illuminated, and you are still
not able to achieve connection, try altering the RF address connection as described in the
section above before repeating steps 1 to 5 (note that the RESET button must be pressed
after altering the address code)
Operating and programming instructions, as well as radiator wall-mounting guidelines are
available on request, and also from the downloads page at www.ecopowerheating.co.uk.
The manufacturer warrants that this item (RT500RF) will be free from manufacturing
defect for a period of 2 years from date of purchase and will repair or replace defective
items for this period under the terms and conditions.
Technical Support: Tel. 01226 323961
Sales:
Ecopower Heating Ltd
252 High Street
Aldershot
Hampshire
GU12 4LP
www.ecopowerheating.co.uk / 0845 474 1478 / [email protected]
Tel. 08454 741478
Installation Instructions