Important safety requirements

Important safety requirements
Important safety requirements
Important safety requirements
Important safety requirements
This hob must be installed in accordance with the Gas Safety (Installation and Use)
Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition).
For appliances installed in the Republic of Ireland please refer to NSAI- Domestic
Gas Installation I.S. 813 Current Editions and the ETCI Rules for Electrical Installations.
Pr Pr Pr Pr Provision for V
ovision for V
ovision for Ventilation
ovision for V
ovision for V
entilation
entilation
entilation
entilation
Detailed recommendations are contained in the following British Standards Codes Of
Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions.
The hob should not be installed in a bed sitting room with a volume of less than 20 m
If it is installed in a room of volume less than 5 m
cm
2
is required. If it is installed in a room of volume between 5 m
of effective area of 50 cm
required.
However, if the room has a door which opens directly to the outside no air vent is
required even if the volume is between 5 m
If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current
Edition, should be consulted to determine the requisite air vent requirements.
For appliances installed in the Republic of Ireland please refer to the NSAI- Domestic
Gas Installation I.S. 813 Current Editions Table Four.
2
is required, while if the volume exceeds 11 m
3
an air vent of effective area of 100
3
3
and 11 m
.
3
and 10 m
3
an air vent
3
no air vent is
3
.
15