Zanussi ZGF 782 CTX Talimat Kitapçığı - Sayfa 13

Hob Zanussi ZGF 782 CTX için çevrimiçi göz atın veya pdf Talimat Kitapçığı indirin. Zanussi ZGF 782 CTX 20 sayfaları. Zanussi instructrion manual gas range zgf 782 ctn, zgf 782 ctx

Wiring Diagram

Fault Finding

Preliminary Electrical Systems
Check
Brown
Blue
Blue
Green
Brown
Yellow
START
Isolate appliance
and carry out:
A: Earth Continuity
check.
NO
YES
Carry out:
C: Polarity check.
Has inlet fuse blown?
NO
YES
Inlet wiring
faulty.
Rectify any
fault.
Isolate appliance and
carry out:
B: Insulation check.
Rectify any fault
including replacing
fuses as necessary.
A. IGNITOR SWITCH
B. IGNITOR UNIT
PLUG (with cover
removed)
( )
Earth Wire
Green/Yellow
Neutral Wire
Blue
Carry out:
D: Resistance to
Earth check.
A. EARTH CONTINUITY CHECK - Appliance must
be electrically disconnected - meter set on Ω
(Ohms) x 1 scale and adjust zero if necessary.
a) Test leads from any appliance earth point to earth
pin on plug. Resistance should be less than
0.1 Ω (Ohm), check all earth wires for continuity
and all contacts are clean and tight.
B. INSULATION CHECK - Appliance electrically
disconnected, all switches ON.
a) meter set on Ω (Ohms) x 1 scale.
Test leads from L to N in appliance terminal
block. If meter reads «0» then there is a short
circuit.
b) meter set on Ω (Ohm) x 100 scale.
Repeat test with leads from L to E. If meter reads
less than ∞ (infinity) there is a fault.
NOTE - Should it be found that the fuse has failed
but no fault is indicated - a detailed continuity check
(i.e. by disconnecting and checking each
component) is required to trace the faulty
component.
It is possible that a fault could occur as a result of
local burning/arcing but no fault could be found under
test. However a detailed visual inspection should
reveal evidence of burning around the fault.
SOCKET
(face view)
( )
E
N
L
Electricity supply
should now be
satisfactory.
13