edges of the hob is 400 mm. If it is fitted below
400 mm a space of 50 mm must be allowed
from the edges of the hob.
For appliances installed in the Republic of Ire-
land please refer to NSAI- Domestic Gas In-
stallation I.S 813 Current Edition Section 7-
Permitted Locations of Appliance.
Gas Connection
Warning! Any gas installation must be
carried out by a GAS SAFE REGISTER
installer.
Make sure that, once the hob is installed, it is
easily accessible for the engineer in the event
of a breakdown.
The manufacturer will not accept liability,
should the above instructions or any of the oth-
er safety instructions incorporated in this in-
struction booklet be ignored.
On the end of the shaft, which includes the G
1/2" threaded elbow, adjustment is fixed so that
the washer is fitted between the components
as shown in the diagram. Screw the parts to-
gether without using excessive force.
1
2
3
End of shaft with nut
1
Washer
2
Elbow
3
Connection to the gas supply should be with
either rigid or semi-rigid pipe, i.e. steel or cop-
per.
The connection should be suitable for connect-
ing to R 1/2 (1/2 BSP male thread).
When the final connection has been made, it is
essential that a thorough leak test is carried out
on the hob and installation.
www.zanussi.com
Make sure that the main connection pipe does
not exert any strain on the hob.
If you use flexible metal pipes make sure that
they agree to ISO 10380 and ISO 10807
standards. Be careful they do not come in
touch with mobile parts or they are not
squeezed. Also be careful when the hob is put
together with an oven.
Important! It is important to install the elbow
correctly, with the shoulder on the end of the
thread, fitted to the hob connecting pipe.
Important! Failure to ensure the correct
assembly will cause leakage of gas.
Important! Make sure that the gas supply
pressure of the appliance obeys the
recommended values.
Rigid connection:
Carry out connection by using metal rigid pipes
(copper with mechanical end).
Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the burn-
er.
3. With a socket spanner 7 remove the injec-
tors and replace them with the ones which
are necessary for the type of gas you use
(see table in "Technical Data" chapter).
4. Assemble the parts, follow the same pro-
cedure backwards.
5. Replace the rating plate (it is near the gas
supply pipe) with the one for the new type
of gas supply. You can find this plate in the
package supplied with the appliance.
If the supply gas pressure is changeable or dif-
ferent from the necessary pressure, you must fit
an applicable pressure adjuster on the gas sup-
ply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob.