ELECTRICAL CONNECTION
Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug (if
applicable).
The appliance must not be connected with an
extension cable, an adapter or a multiple socket.
There is a risk of fire.
Do not let the power cable to heat up to a
temperature of more than 90° C. The cable
should be guided by means of clamps fixed to
the side of the cabinet, in order to avoid any
contact with the appliance beneath the cooktop.
Make sure that there is access to the mains plug
after the installation.
Electrical Requirements
Permanent electrical installation must agree with
the latest I.E.E. Regulations and local Electricity
Board regulations. For your own safety the
installation must be done by a qualified electrician
(e.g. your local Electricity Board, or a contractor
who is on the roll of the National Inspection Council
for Electrical Installation Contracting [NICEIC]).
The manufacturer refuses to be
held responsible, if these safety
measures are not abided by.
Supply connections
This hob has to be connected to 220-240 V (~
50-60 Hz ) electricity supply.
The hob has a terminal block which is
marked as follows:
L — Live terminal
N — Neutral terminal
or E — Earth terminal
Before carrying out the connection, make sure:
1. The limiter valve and the electrical system can
take the appliance load (see the rating plate)
2. The supply system is equipped with an efficient
earth connection in compliance with the current
standards and regulations
3. The outlet or omnipolar switch used for
connection is easily accessible with the
appliance installed.
The appliance is supplied with a 3 core flexible
power cable with a 3 amp plug. If it is necessary to
change the fuse, use a 3 amp ASTA-approved (BS
1362) fuse.
8
A
E
A. Green and Yellow
B. 3 amp fuse
C. Brown
D. Cord clamp
E. Blue
The wires in the cord are coloured as follows:
Green and yellow
Blue
Brown
WARNING! A cut off plug inserted
into a 13 amp socket is a serious
shock hazard. Ensure that the cut off
plug is disposed of safely.
REPLACEMENT OF THE CONNECTION
CABLE
The replacement of electric cable must
be carried out exclusively by the
service force centre or by personnel
with similar competencies, in
accordance with the current
regulations.
To replace the connection cable use
only H03V2V2-F T90 or equivalent
type. Make sure that the cable section
is applicable to the voltage load and
the working temperature. The yellow/
green earth wire (B) must be
approximately 2 cm longer than the
live and neutral wire (A).
B
C
D
- Earth
- Neutral
- Live