Possibilities for insertion
Kitchen unit with door
Proper arrangements must be taken in designing the
forniture unit, in order to avoid any contact with the
bottom of the hob which can be heated when it is
operated. The recommended solution is shown in Fig.
11.
The panel fitted under the hob should be easily
removable to allow an easy access if a technical
assistance intervention is needed.
Fig. 11
a
60
b
FO 1013
a) Removable panel
b) Space possibly useful for
connections
Fig. 14
FO 0939
Fig. 12
FO 0947
Fig. 15
2
120 cm
2
180 cm
FO 0938
Kitchen unit with oven
The hob recess dimensions must comply the indication
given in Figs. 12 and 13 and must be provided with
brackets to allow a continuous supply of air.
To avoid overhating, the building in should be carried out
as shown in Figs. 14 e 15.
The hob's electric connection and the oven's one must
be carried out separately, both for safety reasons and
to allow the oven to be easily taken off the unit.
In case a hood with lenght of 600 mm. is fitted over the
hob, the hanging furniture units beside the hood must
be placed at 550 mm. minimum from the hob, to allow
the fitting and the correct use of the lid, if required (fig.
16).
470
380
140
Fig. 16
2
50 cm
2
360 cm
FO 2099
Fig. 13
550 min.
FO 0198