Technical data

Dimensions
Height:
Width:
Depth: (excluding handles and knobs)
Weight
Space for fixing at hob level 2mm minimum clearance
Space for fixing above hob level See important note 'Location of Appliance'.
Minimum space above hob 650mm (If cooker hood is fitted refer to the cooker hood installation instructions.
Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel)
Connections
Gas connection
Electrical connection
Loading info: Electric ovens
Voltage
Wattage
Loading info: Gas hob
Natural Gas
Heat input
Injector marking
General
Ignition
Spark gap
Gas Gategory
CAT. I
2h
This appliance complies with: European Council Directives Low voltage Directive
73/23/EEC, Gas Directive 90/396/EEC EMC Directive 89/336/EEC, CE Marking Directive
93/68/EEC. Energy Label Directive 2002/40/EC
R.H.F
R.H.R
1.0kW
1.9kW
(3412 Btu/h)
(6483 Btu/h)
070
096
900mm
600mm
600mm
65kg
Rear left hand side of appliance at hob level. Rc ½ (½"
B.S.P. female)
230 - 240 V 50 Hz Mains connected at rear centre of
appliance using at least 6mm
cable.
230-240 Volts AC 50Hz
4.1 – 4.5kW
L.H.R
1.9kW
(6483 Btu/h)
096
(H.T. Spark)
3 – 4 mm
Countries of destination
GB,
multi core PVC insulated
2
L.H.F
2.9kW
(9895 Btu/h)
119