Zanussi ZL 76 AMS Talimat Kitapçığı - Sayfa 17
Ocaklar Zanussi ZL 76 AMS için çevrimiçi göz atın veya pdf Talimat Kitapçığı indirin. Zanussi ZL 76 AMS 22 sayfaları. Mixed fuel cooker 70 cm
Technical Data
Electric Oven ratings
Top/Bottom Heating Element
Grill Element
Convection Fan
Oven light
Total rating
Supply voltage (50 Hz)
Characteristics of Burners, Nozzles and Taps
Burner
Auxiliary
Semi-rapid
Rapid
Double crown
(*) 1 mbar = 10 mm. water coloumn.
Instructions for the installer
Location
In order to function normally it is imperative that this unit
is installed in a well ventilated kitchen (regarding the
installation follow the existing regulations). The appliance
is of freestanding type and must be installed according
to the existing regulations.
For the insertion possibilities, please refer to fig. 12.
The minimum distance combustible material can be fitted
directly above the cooker is 650 mm.
Since the appliance is supplied with
adjustable feet, it should be located as shown
in the diagrams, according to the height
adjustment.
1800 W
1750 W
30 W
15 W
1850 W
230 V
Nominal Power
LPG (Butane "A")
kW
kCal/h
Nozzle
0,95
814
50
1,60
1368
65
2,45
2095
80
3
2562
90
Dimensions of the appliance
Height
Depth
Width
Oven Capacity
Appliance category:
Appliance gas supply:
Diameter
Tap. By-Pass
g/h
75
28
126
35
193
45
236
56
Fig. 12
830/910 mm
600 mm
700 mm
53 dm
LPG 30mbar
Feeding
Pressure
mbar (*)
30
100
100
100
3
I3
17