PARTS IDENTIFICATION

Fig.1

PREPARATION FOR USE

The compressor MUST be filled with oil before use.
A 500mL bottle of Synthetic Oil is provided.
Remove the travel plug, fitted to the Oil Filler/
Breather, and fill with oil using the funnel provided,
so that the level is midway across the Oil Sight Glass
(indicated in Fig.1).
When satisfied, place the breather, contained in
the bag of loose parts, firmly on to the Filler/Breather
spout.

OPERATION

Firstly, ensure the compressor is on level ground...do not allow it
to run if it is standing on an incline.
Check also that the mains voltage corresponds with that
shown on the data label on the side of the compressor.
Ensure that the ON/OFF switch, mounted on the Pressure
Regulator (shown in fig. 3), is turned to the '0' (OFF) position,
then plug in and switch ON at the mains supply.
1.
To start the compressor, turn the ON/OFF switch to the
'I' (ON) position - the motor should start immediately.
NOTE: Should the motor fail to start immediately, it is possible
that the air receiver is already full of air. Check the tank
pressure gauge (see fig. 4). If you release air, by opening
the air drain valve (see fig. 1), the motor will start
automatically once the cut-in pressure is reached.
Fig.2
6