ELECTRICAL INSTALLATION

WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS
SUPPLY.
Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply
through an approved 13 amp BS 1363 plug or a suitably fused isolator switch.
This product may be fitted with a non-rewireable plug. If it is necessary to
change the fuse in the plug, the fuse cover must be refitted. If the fuse cover
becomes lost or damaged, the plug must not be used until a suitable
replacement is obtained.
If the plug has to be changed because it is not suitable for your socket, or
because of damage, it must be removed and a replacement fitted, following
the wiring instructions shown below. The old plug must be discarded safely, as
insertion into a power socket could cause an electrical hazard
WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE
COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL
The colours of the wires in
the power cable must
agree with the markings on
the plug.
• Connect the BLUE wire
to the terminal
marked N.
• Connect the BROWN
wire to the terminal
marked L.
• Connect the YELLOW
AND GREEN wire to the terminal marked E or
AN APPROVED RESIDUAL CURRENT DEVICE (RCD) WHICH HAS A TRIPPING
CURRENT OF LESS THAN 30 mA MUST BE USED.
If you are not sure consult a qualified electrician.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
BROWN = LIVE
Plug must be BS1363/A approved.
Earth
(Green and
Yellow)
Neutral
(Blue)
Ensure that the outer sheath of
the cable is firmly held by the clamp
5
.
YELLOW AND GREEN = EARTH
.
Always fit
a 13 Amp
fuse.
Live
(Brown)