Su Pompası Alemite 8568-A4 için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Alemite 8568-A4 10 sayfaları. Medium-pressure stub pump
Medium-Pressure Stub Pump
Overhaul
N O T E : R e f e r t o F i g u r e 2 f o r c o m p o n e n t
identification on all overhaul procedures.
Prior to performing any maintenance procedure, the following
safety precautions must be observed. Personal injury may occur.
WARNING
Do not use halogenated hydrocarbon solvents
such as methylene chloride or 1,1,1-trichloroethane in this
pump. An explosion can result within an enclosed device
capable of containing pressure when aluminum and/or
zinc-plated parts in the pump come in contact with haloge-
nated hydrocarbon solvents.
Release all pressure within the system prior to performing
any overhaul procedure.
• Disconnect the air supply line from the pump motor.
• Into an appropriate container, operate the control
valve to discharge remaining pressure within the
system.
Never point a control valve at any portion of your body or
another person. Accidental discharge of pressure and/or
material can result in injury.
Read each step of the instructions carefully. Make sure a
proper understanding is achieved before proceeding.
Alemite, LLC
Figure 4 Separation of Pump Tube Assembly from Air Motor
Removal
1. Disconnect the air hose assembly from Air
Motor Assembly (1).
2. Unscrew the pump assembly at Valve Seat
(21) or Bung Adapter (18).
Disassembly
Separate Pump Tube from Air Motor
1. Place the pump assembly in a soft-jaw vise.
• See Figure 4.
2. Unscrew Tube Adapter (5) from the Air
Motor Assembly.
3. Remove Pin (7) that secures Coupling Rod (8)
to the Air Motor Piston Rod.
4. Unscrew the Coupling Rod from the Piston
Rod.
5. Remove the pump tube assembly from the Air
Motor Assembly.
Refer to Figure 2 Parts List
for Parts Identification