Installation

WARNING! Never run the engine in an enclosed space. Ensure adequate
ventilation at all times.
The pump must be situated on a firm, flat, level surface. Make sure that
the pump is placed away from the edge of any pit or pool and cannot
fall in. The suction and discharge fittings supplied with the pump are suitable
for 1" I.D. hose (not supplied). For best performance, keep the suction
pipe as short as possible, and make sure that all connections are airtight.
The pump will not work with air in the suction pipe.
For applications where the suction level is below the pump, we
recommend the use of a foot valve (non-return valve) to retain water in
the suction pipe. To prevent clogging of the pipes or pump, we suggest
that you fit a suction strainer to the end of the suction pipe.
Protect the pipework and the pump from freezing as the formation of ice
in the pump can cause damage. If the pump is installed in a location
likely to freeze, drain the pump (by removing the pump drain plug), and
the pipework after use.