Clarke SPE800 Kullanım ve Bakım Talimatları Kılavuzu - Sayfa 9

Su Pompası Clarke SPE800 için çevrimiçi göz atın veya pdf Kullanım ve Bakım Talimatları Kılavuzu indirin. Clarke SPE800 17 sayfaları.

Clarke SPE800 Kullanım ve Bakım Talimatları Kılavuzu

MAINTENANCE

The only maintenance required is a
regular inspection to ensure that
leaves and other debris is not
blocking the passage of water
through the pump.
If you suspect the pump is blocked
by mud, silt, leaves etc, disconnect it
from the mains supply and backflush
to clear any blockage though the
drain plug.
Always keep the pump in a clean
condition, checking regularly for
loose bolts or a damaged power
cable etc.
If the pump has been used under arduous conditions leading to internal
fouling or damage, the impeller housing can be removed by undoing the four
socket-headed impeller housing bolts shown in Fig 4.
The impeller can then be inspected for damage.
• Note that the pump also includes a 13mm hexagonal connector
used to extend the bolts between pump & motor housing.
STORAGE
After use, drain the pump body whenever there is danger of freezing. If the
pump has been used with contaminated or salty water, it should be
thoroughly flushed with clean water following use, both inside and out. It
should then be drained before replacing the drain plug and storing in a clean
dry environment not exposed to the weather.
In the event that dismantling and overhaul of the pump is necessary, contact
your CLARKE International Service Department on 020-8988-7400.
ACCESSORIES
A wide range of accessories is available, including Filters, Foot Valves, Hoses,
Couplings and 90
information or Clarke International Sales Department on 01992 565333.
These pumps are supplied with a 1" male 90
The use of parts other than genuine Clarke replacement parts may result in
possible safety hazards or decreased machine performance, and will
invalidate your warranty.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
°
Hose Adaptors, etc. Contact your Clarke dealer for further
° hose adaptor.
9