WIRING OF CEILING FAN
1) Total four colors of wires connected from the top of the motor:
* Green – ground wire
* Black(L1), Red(L2), Brown(L3) – live wire for fan
2) Connect motor wires to remote control receiver wires: Black(L1) to
Black(L1), Red(L2) to Red(L2), Brown(L3) to Brown(L3).
3) Connect motor Green wire and remote control receiver wires to AC
wires: White to Neutral, Black to Live, Green to Ground.
4) Earth wire is longer than safety cord by 60mm and more. When the
failure of the suspension system occurs, the current carrying
conductor taut before the earthling conductor and the body of the
fan assembly is still effectively earthed.
9
(WITHOUT LIGHTKIT)
Remote Control Receiver
:
fig 9