WIRING OF CEILING FAN:

1) Total six colors of wires connected from the top of the motor:
* White – neutral wire for lightkit
* Blue – live wire for lightkit
* Black/Red, Red/Brown, Brown/Yellow – live wire for fan
* Green – ground wire
2) Connect motor wires to remote control receiver wires: White to
White ('N' for lightkit), Blue to Blue, Black/Red to Black/Red,
Red/Brown to Red/Brown, Brown/Yellow to Brown/Yellow.
3) Connect motor Green wire and remote control receiver wires to AC
wires: White to Neutral, Black to Live, Green to Ground.
4) Earth wire is longer than safety cord by 60mm and more. When the
failure of the suspension system occurs, the current carrying
conductor taut before the earthing conductor and the body of the fan
assembly is still effectively earthed.
8
REMOTE CONTROL RECEIVER
fig 7