CLEANING & MAINTENANCE
WARNING: NEVER ATTEMPT ANY MAINTENANCE WHILE IT IS CONNECTED
TO THE PROPANE SUPPLY, IS OPERATING, OR IS HOT. (SEVERE BURNS CAN
RESULT).
1. Turn the heater off and let it cool for at least 15 minutes before cleaning.
2. Inspect the heater before each use. Check the connections for leaks.
Apply a mixture of liquid soap and water to the connections. Bubbles
forming indicate a leak. Correct any leaks at once.
3. Keep the heater clean. Clean the heater annually or as needed to remove
dust and debris. If the heater is dirty or dusty, clean with a damp cloth. Use
household cleaners on difficult spots. To clean the reflector, unclip the
guard from the front of the heater.
4. Clean the inside of the heater using compressed air where possible. Blow
air across the burner face until all dust has been dislodged from the surface
(Always wear eye protection when using compressed air).
5. If the hose shows evidence of excessive abrasion or wear or if the hose is
cut it must be replaced prior to the heater being put into operation. The
replacement hose assembly shall be as supplied by CLARKE International.
6. The heater, including hose and regulator assembly, must be inspected at
least annually by a qualified service person.
SPECIFICATIONS
Gas Type
Output
Regulator Pressure
Inlet pressure
Regulator flow rate
Fuel Consumption
Gas Hose Length
Weight unpacked
Dimensions (W x D x H)
Ignition System
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
LPG (Propane)
9.4 kW (30,000 BTU/Hr) (2 x 4.7 kW)
700 mbar (propane)
1-16 bar
2 kg/hr
0.68 kg/hr (2 x 0.34 kg/hr)
1500 mm
3.8 kg
470 x 330 x 500 mm
Piezo
13