Clarus ZF-800 Kullanıcı El Kitabı - Sayfa 13

Su Filtrasyon Sistemleri Clarus ZF-800 için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Clarus ZF-800 20 sayfaları. Treatment systems

Clarus ZF-800 Kullanıcı El Kitabı
as depth and digestion increases. More than 15" (38
cm) may require a reduction in recirculation rate. A
sludge accumulation of greater than 24" (61 cm) in
the sedimentation and 15" (38 cm) in the anaerobic
chamber requires pumping.
PART C: Sedimentation Chamber – collect samples from
the outlet baffle of the sedimentation chamber for the
following analyses:
1.
Scum – 0" to 12" (0-30.5 cm) is common, so long as it
is not rising above the partition wall. If so, punch down
using ladle.
2.
Sludge – A range of 0" to 24" (0-61 cm) is common.
Typically brown and settled, becomes gray or black as
depth and digestion increases. A sludge accumulation
of > 24" (61 cm) in the sedimentation chamber and 15"
(38 cm) in the anaerobic chamber requires pumping.
RECIRCULATION
BAFFLE
Figure 17
- Inspection details
RECIRCULATION
INFLOW
BAFFLE
SLUDGE RETURN
INFLOW
TOP VIEW
BAFFLE
SLUDGE RETURN
OPTIONAL WATER QUALITY ANALYSES
PART A: Clean Water Storage Chamber – Collect samples from the clean water storage chamber to be used for the
following analyses
1. pH – Measures the hydrogen ion-concentration and is determined with the use of the pH test strips included in the
Fusion
Maintenance Kit. Dip a test strip into the water sample for 1 second, remove, and read by comparing to the color
®
chart provided on the container. A pH = 7.0 is neutral. The range suitable for biological activity is 6.5 to 7.5. Recurring
results outside this range should be investigated – check the water source for the home or business, chemical use, etc.
2. NO
N – Determined with the use of the nitrite test strips included in the Fusion
-
2
the water sample for 1 second, remove, allow to react for 30 seconds and read by comparing to the color chart provided
on the container. Nitrite-nitrogen is an intermediate step in the oxidation of ammonia to nitrate and the reduction of
nitrate. 0 to 3 mg/L is common and 1mg/L is average. The presence of nitrite is indicative of biological activity. The
absence of nitrite could be due to a young system or a recirculation rate that is too high. To correct low nitrite readings
in established systems, decrease the recirculation rate.
FUSION
OPERATION AND MAINTENANCE, continued
®
BAFFLE
EFFLUENT
BACKWASH
(RED)
AERATION
(BLUE)
BACKWASH
(RED)
AERATION
(BLUE)
TOP VIEW
RECIRCULATION
G.L
INFLOW
BAFFLE
6" (152mm) STONE OR CONCRETE PAD
EFFLUENT
© Copyright 2020. All rights reserved.
13
WALL OPENING
W.L
W.L
W.L
RECIRCULATION
WALL OPENING
G.L
W.L
W.L
INFLOW
RECIRCULATION
BAFFLE
SIDE VIEW
RECIRCULATION
6" (152mm) STONE OR CONCRETE PAD
SIDE VIEW
Maintenance Kit. Dip a test strip into
®
G.L
W.L
EFFLUENT
BAFFLE
G.L
W.L
W.L
EFFLUENT
WALL OPENING
BACKWASH MECHANISM
BAFFLE
WALL OPENING
BACKWASH MECHANISM
SK3194