Lenovo A516 Servis Kılavuzu - Sayfa 32

Cep Telefonu Lenovo A516 için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Lenovo A516 40 sayfaları.
Ayrıca Lenovo A516 için: Hızlı Başlangıç Kılavuzu (6 sayfalar), Kullanıcı Kılavuzu (35 sayfalar), Önemli Ürün Bilgileri Kılavuzu (20 sayfalar)

Lenovo A516 Servis Kılavuzu
Repair Manual of Lenovo A516 Mobile Phone

4.3.2 High Frequency Error

Fault: Frequency Error exceeds standard in complete set test.
Cause: There is problem in VAFC input circuit of TCXO.
Shooting:
is in cold solder joint or damaged
Replace the elements in
joint

4.3.3 High Phase Error

Fault: Phase Error exceeds standard in complete set test.
Cause: The capacitors of power supply part of PA and transceiver are in cold solder joint
or in short circuit with other resistance.
Shooting:
Excessive
Frequency Error
Recalibrate
Check whether U2104
cold solder
32