Armstrong 3031S Kurulum ve Bakım Kılavuzu - Sayfa 10

Kontrol Ünitesi Armstrong 3031S için çevrimiçi göz atın veya pdf Kurulum ve Bakım Kılavuzu indirin. Armstrong 3031S 20 sayfaları. Water temperature controls groups of fixtures - thermostatic

Step 1
b
a
a. Unscrew the set screw.
b. Remove the Backplate.
Step 3
a. Important! Prior to assembly of the hot and cold
adapters, look inside each one and ensure that there
is a strainer and a white plastic checkvalve. The
adapter with nothing inside is for the outlet.
Thread the coupling nuts onto the Valve assembly
then tighten using an adjustable spanner.
Caution! Use a soft cloth to protect the plating
from damage while tightening the spanner.
Step 2
1
4
Ø 6 mm
2.5 mm
a. Use the Backplate to mark the four mounting holes at
the desired height.
b. Drill the holes (6 mm) and fit the wall anchors. Screw
the Backplate to the wall.
Caution! Avoid area where underground wirings
or pipelines pass through.
Step 4
a. Mount the Valve assembly on the Backplate fixed on
the wall. Make sure the Valve assembly locks in the
groove.
b. Tighten the set screw.
10
3
2
6.0 mm
2.5 mm