Dirt Killer Pressure Washer Operator's Manual
ACCESSORIES INCLUDED
Gunjet Lance
High Pressure Hose
Injector
Nozzles - See model type for list:
Models: H200 / H260 / H357 - Vario Jet Nozzle,
Dirt Killer Nozzle
Models: H360 / E300 - Flat Tip Nozzle Set
(0, 15, 40, Soap), Industrial Dirt Killer Nozzle
Models: E3000 / H3612 - Flat Tip Nozzle Set
(0, 15, 40, Soap
INSTALLATION INSTRUCTIONS
1. Remove pressure gauge cover. You will notice
that the pressure gauge is filled with liquid. This is
glycerin, not water. The glycerin dampens the
movement of the pressure gauge needle to insure
long life.
2. Check the oil level on your pressure washer.
Do this by checking the dip stick on the top of the
pressure washer pump. The oil level must be
between the flat blade of the dip stick. If the oil is
milky or very dark in color consult a technician
before operating the pressure washer
2. If the pressure washer is equipped with a hose
reel, unroll the hose from the hose reel insuring
that there are no kinks. Insure that the high
pressure hose is not a tripping hazard.
(WARNING - High pressure hose can be damaged
if run over by a heavy object such as a vehicle).
3. Connect your gun jet onto the high pressure
hose. Insure that all quick couplers have o-rings or
your pressure washer will leak from the quick
coupler connector.
WARNING - Insufficiently tightened fittings may
tear o-rings and leak when the pressure washer is
operating. .
4. Insure a water filter is installed on the water
inlet. Check the water filter to insure that it is free
of dirt or debris. Connect your unit to a water hose
making sure that your supply hose is at least 5/8"
diameter and has no leaks, or kinks. (For pressure
washer of greater then 3.5 gallons per minute use
a 3/4" garden hose to insure proper inlet water
flow). If there are leaks make necessary repairs.
Insure that you turn on the water spigot completely
so that the full flow is obtained. The inlet water
should be cold; the temperature may not exceed
140 F. Be sure your unit receives its full water flow
requirement.
WARNING - Insufficient inlet water flow can cause
cavitation resulting in pump damage.
5. If using cleaning chemical with your pressure
washer, mix your cleaning agents in a separate
clean container adhering to manufacturer's
recommended dilution ratios. Submerge the
chemical pickup line into the solution.
6. If you are using an electric pressure washer, be
aware of the voltage and amperes stamped on
motor. Unroll the power cord completely. Insure
the power cord is not in a place where it will be a
tripping hazard or will get wet. Plug the cord into
Oil level
an outlet that will provide sufficient voltage and
amperage to the unit. On 110 volt machines al-
ways use ground 12-3 gauge UL approved
extension cords. Never run more than 50 feet of
extension cord from the source.
3