Armstrong 3750 Kurulum ve Kullanım Talimatları Kılavuzu - Sayfa 4
Kontrolör Armstrong 3750 için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Talimatları Kılavuzu indirin. Armstrong 3750 14 sayfaları. Pulpress pressurisation unit
i nsta ll at ion &
operat in g in str uct ion s
4
please read all these notes carefully,
1.0 ce conformities
lvd
Low voltage switchgear
Safety of machinery
Safety of machinery
Electromagnetic compatibility
Harmonic emissions
Electrostatic discharge
Radiated rf immunity
Fast transient bursts
Voltage surges
Conducted rf immunity
Voltage dips
Generic immunity
Generic immunity
Generic emissions
Generic emissions
Safety of stationary circulation
pumps for heating and service
water installations
2.0 preface
1 The 3750 Pulpress pressurisation unit has been designed
for ease of setting and operation
2 All packaged pump systems are pre-wired and fully tested,
both hydraulically and electrically, prior to dispatch.
3 All parameter data has been entered into the controller
in accordance with the system criteria. Once on-site
connections have been made, and all pre-checks carried
out, the system is ready for commissioning.
4 During commissioning if system conditions are found
to vary from those set out in the design criteria, the
parameters can be easily changed
3 .0 introduction
1 This installation and operation manual contains specific
information regarding safe installation and operation of
the 3750 Pulpress pressurisation unit. These instructions
must be read and understood by anyone responsible for
the installation and maintenance of this equipment.
2 Prior to power being applied, it is essential that all
pre-commissioning procedures are carried out in full.
3 Operators and installers must familiarise themselves with
the operation and controls of the equipment.
3750 Pulpress
pressurisation unit
bs en 61010-1
bs en 60439-1
bs en iso 12100-1&2
bs en 60204-1
bs en 61000-3-2
bs en 61000-4-2
bs en 61000-4-3
bs en 61000-4-4
bs en 61000-4-5
bs en 61000-4-6
bs en 61000-4-11
bs en 61000-6-1
bs en 61000-6-2
bs en 61000-6-3
bs en 61000-6-4
bs en 60335-2-51
4 .0 warnings symbols
Safety instruction where an electrical hazard is
involved.
Safety instruction where non-compliance would
affect safety.
Safety instruction relating to safe operation of the
equipment. (attention)
5 .0 instructions for safe use
1 This equipment has been designed for the pressurisation
of sealed heating, chilled water and closed condenser
water systems to the operating conditions shown.
2 No installation of this equipment should take place until
this installation, operation and maintenance instructions
has been studied and understoodby the person
responsible.
3 Handling, transportation and installation of this equipment
shall only be undertaken with the proper use of lifting gear.
4 The set shall not be used for any purpose other than that
for which it was designed and sized.
The set shall not be operated with the cover
5
removed and the cover interlocked isolator
overridden.
note:
During normal operation the pumps will only
generate pressures sufficient to satisfy system de-
mand. However, abnormal running conditions may
cause closed valve pressures to be experienced.